3.5
Shut-down warning
Description
A shut-down warning will appear in the event of:
• Too high a temperature at the outlet of the compressor element
• Too high a dewpoint temperature (Full-Feature compressors)
Compressor element outlet temperature
• If the outlet temperature of the compressor element exceeds the shut-down warning level (see section
Programmable settings), warning LED (5) starts blinking.
• Press the Scroll down button. The screen shows the temperature at the compressor element outlet:
The screen shows that the temperature at the element outlet is 120 °C
It remains possible to scroll through other screens, using the Scroll buttons up and down (12) to check the
actual status of other parameters. Press button (11) to stop the compressor and wait until the compressor
has stopped. Switch off the voltage, inspect the compressor and remedy. The warning message will
disappear as soon if the warning condition disappears.
Dewpoint temperature
On compressors with integrated dryer, alarm LED (5) will light up and the related pictograph will appear
flashing if the dewpoint temperature exceeds the warning level (programmable).
Main screen with the dewpoint temperature warning
The related pictograph
will appear flashing
Press the Scroll button (12) until the actual dewpoint temperature appears.
Instruction book
24
2920 7101 41