For technical questions, please call 1-800-444-3353.
12 volt Dc Fuse (8):
8.
The 12 Volt DC Outlet has
one
Fuse (8) to protect the Gen-
erator from overloading. The Generator is equipped with the following size and type
of Fuse:
F10A250v
. Should a 12 VDC output exceed the fuse’s rating, always
check to see if the Fuse has “blown” (a melted filament within the Fuse). If neces
-
sary, unplug all electrical loads from the Generator, replace with a new Fuse, and
reattach a reduced load to the generator.
(See Figure c.)
Power-On Light (10):
9.
Indicates voltage is being provided by the Generator.
(See Figure c.)
PRE-START iNSTRucTiONS
To Add Engine Oil:
cAuTiON!
1.
Your warranty is voided if you do not put engine oil in the Engine’s
crankcase prior to its first use. Before each use, check the oil level. Never run the
Engine with low or no engine oil. Running the engine with low or no oil will perma-
nently damage the Engine.
OiL DiPSTicK
(65A)
FuEL TANK
(31)
FuEL GAuGE
(35)
FuEL FiLTER
(32)
FuEL TANK cAP
(34)
FiGuRE D
2.
The Engine
MuST
be filled with a high quality grade engine oil. If the Engine will
be run in temperatures
above
32 degrees Fahrenheit, use
SAE 10W-30
weight oil.
ThiS GENERATOR
hAS AN AuTO-
ShuTDOWN OiL
SENSOR. iF
ENGiNE STOPS OR
WiLL NOT START,
chEcK OiL LEvEL.