Chicago Electric 98332 Set Up And Operating Instructions Manual Download Page 5

SKU 98332 

For technical questions, please call 1-800-444-3353. 

Page 5

approved safety equipment, such as 

those dust masks that are specially 

designed to filter out microscopic 

particles.  (California Health & Safety 

Code § 25249.5, 

et seq.

)

Cleaning may produce Aluminum 

6. 

Oxide dust which can cause eye, skin 

or breathing irritation. Always use a 

NIOSH approved respirator, safety 

goggles and rubberized gloves when 

operating this tool.
Always use water based solvents 

7. 

when operating this tool. Water based 

solvents have a pH greater than 7. 

Use of other types of solvents may 

cause injury. 

DO NOT use any highly flammable, 

8. 

volatile or combustible solvents such 

as gasoline, kerosine, etc. in this tool.
Parts being cleaned may deposit oil, 

9. 

grease, gasoline or other combustible 

contaminants in the tool. Check for 

volatile fumes, and use this tool only 

in a well-ventilated area. 
WARNING: Chlorinated solvents 

10. 

such as 1-1-1 Trichloroethane and 

Methylene Chloride can chemically 

react with aluminum and may ex-

plode. Many parts contain aluminum. 

Do not clean aluminum parts with 

these solvents.
WARNING: Handling the cord on 

11. 

this product will expose you to lead, 

a chemical known to the State of 

California to cause cancer, and birth 

defects or other reproductive harm. 

Wash hands after handling.  (Califor-

nia Health & Safety Code §  25249.5, 

et seq.)
The warnings, precautions, and in-

12. 

structions discussed in this instruction 

manual cannot cover all possible con-

ditions and situations that may occur.  

It must be understood by the operator 

that common sense and caution are 

factors which cannot be built into this 

product, but must be supplied by the 

operator.

  saVe these 

instructions.

GroundinG

 

to PreVent 

electric shocK 

and death From 

incorrect GroundinG 

Wire connection: 

Check with a qualified 

electrician if you are in doubt 

as to whether the outlet is 

properly grounded.  do not 

modify the power cord plug 

provided with the tool.  never 

remove the grounding prong 

from the plug.  do not use the 

tool if the power cord or plug 

is damaged.  if damaged, have 

it repaired by a service facility 

before use.  if the plug will not 

fit the outlet, have a proper 

outlet installed by a qualified 

electrician.

Summary of Contents for 98332

Page 1: ...manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent o...

Page 2: ...ith the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION wit...

Page 3: ...b ment Always wear eye protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropri ate conditions will reduce personal injuries Prevent uninte...

Page 4: ...e instructions taking into account the working conditions and the work to be performed Use of the power tool for operations different from those intended could result in a hazardous situation Service...

Page 5: ...m and may ex plode Many parts contain aluminum Do not clean aluminum parts with these solvents WARNING Handling the cord on 11 this product will expose you to lead a chemical known to the State of Cal...

Page 6: ...and grounded in accordance with all codes and ordinances The plug and outlet should look like those in the preceding illustration See 3 Prong Plug and Outlet Double Insulated Tools Tools with Two Pron...

Page 7: ...icate it is acceptable for outdoor use Make sure the extension cord is prop 7 erly wired and in good electrical con dition Always replace a damaged extension cord or have it repaired by a qualified el...

Page 8: ...ury from accidental operation Turn the Power Switch of the tool to its OFF position and unplug the tool from its electrical outlet before assembling or making any adjustments to the tool Note For addi...

Page 9: ...or use of this product Tool Set Up To prevent serious injury from accidental operation Turn the Power Switch of the tool to its OFF position and unplug the tool from its electrical outlet before perfo...

Page 10: ...ork Basket 8 2 may be used to soak support or drain parts during the cleaning pro cess When work is completed press the 9 Switch 23 to the OFF position Remove cleaned parts 10 Shut the Cover 1 11 To p...

Page 11: ...e solvent will be splashed and spilled Prepare the area to contain spilled solvent Remove the Drain Plug 11 by turn 4 ing it counterclockwise Solvent will pour out of the Body 7 5 into the container W...

Page 12: ...th 1 36 Hex Screw 1 37 Locking Caster 2 38 Caster 2 39 Washer 4 40 Nut 4 PLEASE READ THE FOLLOWING CAREFULLY The manufacturer and or distributor has provided the parts list and assembly diagram in thi...

Page 13: ...ge 13 ASSEMBLY DIAGRAM Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes...

Page 14: ...idental or consequential damages so the above limitation of exclusion may not apply to you This warranty is express ly in lieu of all other warranties express or implied including the warranties of me...

Reviews: