![Chicago Electric 65712 Set Up And Operating Instructions Manual Download Page 23](http://html.mh-extra.com/html/chicago-electric/65712/65712_set-up-and-operating-instructions-manual_2598282023.webp)
SKU 65712
For technical questions, please call 1-800-444-3353.
Page 23
setting closing Force:
Figure ii
Figure JJ
15. Press and hold the
“set”
Button for more than four seconds. The Digital Display
will indicate
“1”
. Repeatedly press the
“up”
Button until the Digital Display indicates
“4”
. Press and release the
“set”
Button. The Digital Display will indicate a flashing
“4”
. Now the unit enters into the
close force
mode.
(see Figures ii and JJ.)
(1-9)
Figure kk
(9-1)
Figure ll
16. Press and release the
“up”
Button. The Digital Display will show a flashing
“1” - “9”
(default value is
“4”
) which indicates the open force level.
“1”
is the
minimum force, and
“9”
is the maximum force. Each time you press and release
the
“up”
Button, the figure increases by 1, and the force increases to a higher
level. Each time you press and release the
“doWn”
Button, the figure decreases
by 1, and the force decreases to a lower level.
(see Figures kk and ll.)
Figure mm
Figure nn
17. Press the
“set”
Button to store the data when the open force is set. The Digital
Display will indicate a steadily glowing
“4”
. The unit is ready for setting another
parameter. If no other setting is to be programmed right now, press the
“set”
Button. The Digital Display will indicate
“h”
. Now the
close force
setting is fin
-
ished.