For technical questions, please call 1-888-866-5797.

Item 62297 

        

S

AFETY

O

PERA

TION

M

AINTENAN

c

E

S

ETUP

Grounding

TO PREVENT ELEcTRIc SHOcK AND DEATH FROM 
INcORREcT GROUNDING WIRE cONNEcTION: 
check with a qualified electrician if you are in doubt as to whether the outlet is properly 
grounded.  Do not modify the power cord plug provided with the tool.  Never remove the 

grounding prong from the plug.  Do not use the tool if the power cord or plug is damaged.  If damaged, have 
it repaired by a service facility before use.  If the plug will not fit the outlet, have a proper outlet installed by 
a qualified electrician.

Grounded Tools: Tools with Three Prong Plugs

3-Prong Plug and Outlet

1.  Tools marked with “Grounding Required” have 

a three wire cord and three prong grounding 
plug.  The plug must be connected to a properly 
grounded outlet.  If the tool should electrically 
malfunction or break down, grounding provides 
a low resistance path to carry electricity away 
from the user, reducing the risk of electric shock.  

(See 3-Prong Plug and Outlet.)

2.  The grounding prong in the plug is connected 

through the green wire inside the cord to the 
grounding system in the tool.  The green wire 
in the cord must be the only wire connected to 
the tool’s grounding system and must never 
be attached to an electrically “live” terminal.  

(See 3-Prong Plug and Outlet.)

3.  The tool must be plugged into an appropriate outlet, 

properly installed and grounded in accordance 
with all codes and ordinances.  The plug and outlet 
should look like those in the preceding illustration.   

(See 3-Prong Plug and Outlet.)

Double Insulated Tools: Tools with Two Prong Plugs

Outlets for 2-Prong Plug

1.  Tools marked “Double Insulated” do not 

require grounding.  They have a special 
double insulation system which satisfies OSHA 
requirements and complies with the applicable 
standards of Underwriters Laboratories, Inc., 
the Canadian Standard Association, 
and the National Electrical Code.

2.  Double insulated tools may be used in either of the 

120 volt outlets shown in the preceding illustration.   

(See Outlets for 2-Prong Plug.)

Summary of Contents for 62297

Page 1: ...future reference 18b When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2014 by Harbor Freig...

Page 2: ...tion which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMPORTANT SAFETY INFORMATION General Power Tool Safety Warnings Read all safety wa...

Page 3: ...cohol or medication A moment of inattention while operating power tools may result in serious personal injury 2 Use safety equipment Always wear eye protection Safety equipment such as dust mask non s...

Page 4: ...nd specifications provided with this power tool Failure to follow all instructions listed below may result in electric shock fire and or serious injury 2 Operations such as grinding wire brushing or c...

Page 5: ...he power tool near flammable materials Sparks could ignite these materials 16 Do not use accessories that require liquid coolants Using water or other liquid coolants may result in electrocution or sh...

Page 6: ...up The operator can control torque reactions or kickback forces if proper precautions are taken 2 Never place your hand near the rotating accessory Accessory may kickback over your hand 3 Do not posit...

Page 7: ...injuries nervous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any medical or physical symptoms related to vibration such as tingling numbness and white or blue...

Page 8: ...to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the gro...

Page 9: ...d outdoors make sure it is marked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always...

Page 10: ...ETY OPERATION MAINTENANcE SETUP Specifications Rating 120 VAC 60 Hz 10 A No load speed 1000 3500 RPM Maximum Accessory Size 7 Diameter Mounting Disc Type 7 Hook Loop Variable Speed Switch Sliding Butt...

Page 11: ...rom its electrical outlet before assembling or making any adjustments to the tool Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near t...

Page 12: ...ile working 3 Secure loose workpieces using a vise or clamps not included to prevent movement while working 4 There must not be hazardous objects such as utility lines or foreign objects nearby that w...

Page 13: ...as much wax in subsequent applications d Resume operation Note The most common error when waxing polishing a vehicle is applying too much wax If the Foam Pad becomes saturated with wax applying wax w...

Page 14: ...h is in the off position then plug in the tool 4 Turn the Power Switch to its ON position to start the tool 5 Wait until the tool has reached full speed then gently contact the surface 6 Keep heavy pr...

Page 15: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Page 16: ...nce and Lubrication 1 BEFORE EAcH USE inspect the general condition of the tool Check for loose hardware misalignment or binding of moving parts damaged cord electrical wiring cracked or broken parts...

Page 17: ...d load See Extension Cords in GROUNDING section Performance decreases over time Carbon brushes worn or damaged Have qualified technician replace brushes Excessive noise or rattling Internal damage or...

Page 18: ...Button 1 8 Speed Button 1 9 Screw 3 10 Switch Base 1 11 Circuit Board 1 12 Display 1 13 Switch Button 1 14 Screw 1 15 Housing 1 16 Bearing Housing 1 17 Magnet Ring 1 18 Seal Ring 1 19 Bearing 627 1 20...

Page 19: ...Page 19 For technical questions please call 1 888 866 5797 Item 62297 SAFETY OPERATION MAINTENANcE SETUP Assembly Diagram...

Page 20: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPL...

Reviews: