![Chiaravalli CHPL Series Installation, Maintenance And Operation Instructions Download Page 11](http://html1.mh-extra.com/html/chiaravalli/chpl-series/chpl-series_installation-maintenance-and-operation-instructions_2597881011.webp)
6
1.
GENERAL INFORMATION
CHPL / CHPLB
Hoop equipped (swab)
Load hook
Screw hook
Locked hook
Manuel lifting (Weight ≤ 55 kg)
(ref. ILO Contract)
Not valid for the continuous carrying.
1.6
Storage
The certain suggestions have given about the storage conditions of the gear unit/gear unit with motor below;
●
In clear and moist-airs, the storage should not be made.
●
The gear unit/gear units with motor should not directly be contacted to the ground.
●
The place must be moveless where the both gear unit/gear units with motors are contacted. Otherwise there
could be damage during the movement.
●
The gear unit should be got into the secure to the falling.
●
The processed surfaces of the gear units and both solid and hallow shafts must be lubricated with protective
oil.
●
Gear unit/Gear units with motors must be in the place where there will be no big temperature differences
between -5 and 40.
●
Relative humidity must be less than %60.
●
Not directly be exposed to sunlight and infraded light.
●
Must be kept away from the abrasive materials which causes corrosion (dirty weather, ozon, gases, solvents,
acids, salts, radioactivity, etc.) in environment.
●
The protective oil SHELL ENSIS or similar product should be used on the corrodible pieces.
●
If the gear unit is without oil, it must
be filled with lubrication
oil.
1.6.1
Long Term Storage Suggestions;
●
Mineral oil and synthetic oil according to the mounting position are filled to get ready for operating. Despite
this, the oil level must be controlled before operating.
●
The VCI Corrosion protected tool are mixed into the gear unit's oil.
●
The carrying safety of the ventilation plug must not be removed during the storage.
●
The gear unit must be closed to the shape of unleaked.
NOTE!
- In the long-term storage or during the short-term storage, if the excessive temperature
differences occurs, the oil in the gear unit must be changed before the operating.
-
In the fully oil filled gear unit, the oil level should be reduced according to the
mounting
position.
A
A
A