Operation
Installation Of The Tapered Shank
1.
Disconnect from the main power supply, before you replace the cutter.
2.
Remove the protective cover (a).
3.
Wipe the spindle sleeve and taper shank.
4.
Put the taper shank (i) into the spindle sleeve. Matt the cutter with an oilcloth.
5.
Use a #14 openend wrench (c), turning the spindle draw bar (clockwise) (b), in order to secure
the tapered shank.
6.
Pull out the fixing pin
7.
Install the protective cover (a).
Removal Of The Tapered Shank
1.
Disconnect from the main power supply, before you replace the cutter.
2.
Remove the protective cover (a).
3.
Use a#14 openend wrench (c), to loosen the spindle draw bar (counterclockwise) (i), in order
to remove the tapered shank.
4.
Knock the taper shank (i) (gently with a plastic hammer) to loosen it in the spindle sleeve.
5.
Matt the cutter with an oilcloth.
6.
Install the protective cover (a).