Installation instruction Meanwell LCM40 
v2.0 / 25-08-2020 

www.chess.nl 

Installation 

 

Mount the Meanwell LCM40 in the direct neighborhood of other Mymesh products. 

 

The Meanwell LCM40 contains an antenna for wireless communication with other Mymesh products. 
Operation of the antenna should not be disrupted. 

o

 

Ensure that the antenna (top side) is pointing upright. 

o

 

Do not mount the Meanwell LCM40 inside a metal housing or directly next to a large metal 
object. 

o

 

Some glass and plastic materials influence the operation of an antenna. 

o

 

Contact Chess in case of doubt. 

 

Connect the LED lamp to Vo- and Vo+ and connect the mains power to AC/N and AC/L (see 
schematic below). 

 

Configuration 

The output current of the Meanwell LCM40 can be adjusted to various settings by means of a DIP switch 
(see table below). 

Voltage 
range 

Selectable 
current 

DIP switch setting

1

 

Voltage 
range 

Selectable 
current 

DIP switch setting

1

 

2-100 V 

350 mA 

 

2-57 V 

700 mA 

 

2-80 V 

500 mA 

 

2-45 V 

900 mA 

 

2-67 V 

600 mA 

 

2-40 V 

1050 mA 

 

(1) the white square indicates the position of the DIP switch

 

 

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON