Figure 5
Figure 7
Figure 8
Figure 10
Figure 9
Figure 11
Figure 6
TOOLS NEEDED:
P1444
PROCEDURE:
Follow step in figures 5 through 10; hold the installed wrap with
one hand, while sliding the tool P1444 over the entire hose length
(similar to using a zipper) to complete the operation.
Wrap tape around the 2 ends of the wrap.
UN-WRAPPING HYDRAULIC HOSES
Figure 12: Unwrap the tape then pull the wrap sideways starting
from one end (figure 11).
MAINTENANCE AND REPAIR
Note: Minor fluid loss over time at the piston rod is normal, and does not indicate seal damage.
See troubleshooting guide (page 8) for simple tips on when tool maintenance or repair is necessary.
Always remove the air source from the tools prior to performing any maintenance work.
Establish a maintenance schedule according to your production needs to ensure optimum riveter operation
Inspect routinely for fluid leaks around plugs, screws and fittings, moving parts.
RECOMMENDED FLUID
Automatic transmission fluid, Dexron
®
III (no substitutes).
PROPERTIES: Specific gravity: 0.863
Weight per gallon: 7.18 lbs.
Open flash point: >200°C (392°F)
RECOMMENDED BRAND: ATF Dexron
®
III. The data herein is for your reference; for the latest MSDS, check with the fluid manufacturer.
DEXRON III
®
FLUID SAFETY DATA
HANDLING:
Eye protection required. Protective gloves,
chemical-resistant boots and apron are recom-
mended.
Use in well ventilated area.
FIRST AID
If irritation develops, please consult a physician.
Skin:
Wash thoroughly with soap and water as soon as pos-
sible. Casual contact requires no immediate attention.
Eyes:
Flush with abundant water.
Ingestion:
Seek medical attention immediately.
DO NOT INDUCE VOMITING.
Inhalation:
Remove from contaminated area; apply artificial
respiration if needed. If unconscious, consult physician.
No significant adverse health effects expected from short
term exposure.
ENVIRONMENT
Storage:
Avoid storage near any ignition source, including
open flame
Waste Disposal:
In accordance with applicable regulations.
Spillage:
Prevent entry into drains, sewers and water
courses. Soak up with diatomaceous earth
or other inert material. Dispose in
accordance with applicable regulations.
Combustibility:
Slightly combustible if heated above flash
point. It will release flammable vapors
which can ignite or be explosive in con-
fined spaces if exposed to source of ignition.
Fire:
Use suitable extinguishing media: dry powder, foam,
and CO2 or water fog. Do not use water jets.
PROTECTING THE HIGH PRESSURE HOSES
4
Summary of Contents for G84-LS
Page 10: ...G84 LS CROSS SECTIONAL VIEW 10...