S23 Micro Vacuum Liquid Pump Series

User Guide

Copyright © Chengdu Hilin Technology Co., Ltd.

3

2

Functions

2.1

Speed Control Feature

The flow can be changed by adjusting the motor speed of the pump

(by adjusting the PWM duty cycle).

2.2

Start-Stop Function

The start and stop of the pump can be controlled by the start and

stop control level signal, which is suitable for frequent start and stop

working conditions.

2.3

Speed Feedback

The speed of the pump can be obtained through the speed feedback

signal, easy to realize working condition monitoring and

closed-loop control.

Summary of Contents for Hilintec S23 Series

Page 1: ...Copyright Chengdu Hilin Technology Co Ltd 1 S23 Micro Vacuum Liquid Pump Series User Guide Issue 09 Date 2020 07 10...

Page 2: ...and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all sta...

Page 3: ...guide relevant technical personnel to initially understand the characteristics of the product Intended Audience This document is intended for technical personnel You should have a good understanding o...

Page 4: ...icial release initially determine the product model 02 2019 4 01 XYL Modify some parameters 03 2019 5 01 XYL Modify the logic wiring diagram and wire sequence 04 2019 9 01 LYZ Modify the document form...

Page 5: ...s liquid Dual Purpose 2 2 Functions 3 2 2 Start Stop Function 3 2 3 Speed Feedback 3 3 Technical Specifications 4 3 1 Key Specifications 4 3 2 Description of Versions 5 3 3 Working Conditions 5 3 4 Pu...

Page 6: ...S23 Micro Vacuum Liquid Pump Series User Guide Copyright Chengdu Hilin Technology Co Ltd IV 7 Dimensions 14 8 Appearance 16...

Page 7: ...eighs about 80g and the overall size is about 35 51 56mm 1 2 Brush less DC Motors This model is driven by brush less motor which has the advantages of long service life low interference and high relia...

Page 8: ...The internal double sealing structure offers good air tightness making this series of pumps suitable for applications requiring high air tightness 1 5 Gas liquid Dual Purpose Liquid gas dual use can...

Page 9: ...f the pump by adjusting the PWM duty cycle 2 2 Start Stop Function The start and stop of the pump can be controlled by the start and stop control level signal which is suitable for frequent start and...

Page 10: ...input voltage requires 12V 10 2 Unless otherwise specified the technical parameters are measured under the conditions of temperature 25 and standard atmospheric pressure of 101kPa For products with ot...

Page 11: ...est which is expected value 3 3 Working Conditions 1 Environment The permissible ambient temperature temperature of the pump is 0 50 the pump should avoid exposure in the sun and should work in a clea...

Page 12: ...temperature 5 33 fluctuates with the climate relative humidity less than 90 fluctuates with the climate 2 Simplified version as a gas pump lifetime 3000h as a liquid pump lifetime 1500h Standard vers...

Page 13: ...length mm Outlet Testing suction Inlet Testing discharging Clean Water 20 101 Silicone rubber hose 4 100 100 Note 1 The maximum average flow rate of the curve will be slightly lower than the nominal v...

Page 14: ...rent curve is measured under the working condition that the inlet and outlet are filled with water and there are certain individual differences between different micro pumps This curve is a statistica...

Page 15: ...ium version Note If the remarks starts with a letter it means a special custom function For example letter GJ means customized high temperature medium function and GH means customized high temperature...

Page 16: ...the power supply 2 Red Positive pole of the power supply DC12V 10 3 Yellow FG feedback signal motor speed feedback signal pulse signal the motor outputs 6 pulses per rotation Output 4V High Level Low...

Page 17: ...r supply and the black white and orange wires connected to the negative pole of the power supply the yellow wire shall be insulated and wrapped and the pump will work at the rated speed When you need...

Page 18: ...ost computer etc that supports PWM signal output FG signal input and start stop control Connect the signal source output to the white PWM input wire and connect the PWM signal source ground to the DC...

Page 19: ...explosive environments 2 Foreign matter must not fall into the hydraulic connectors and there should be no solid particles in the medium otherwise the micro pump will be damaged 3 When this product is...

Page 20: ...S23 Micro Vacuum Liquid Pump Series User Guide Copyright Chengdu Hilin Technology Co Ltd 14 7 Dimensions...

Page 21: ...logy Co Ltd 15 Installation instructions 1 The screws on the pump cannot be removed otherwise it will damage the pump 2 The mounting holes are self tapping screw holes not suitable for repeated tighte...

Page 22: ...S23 Micro Vacuum Liquid Pump Series User Guide Copyright Chengdu Hilin Technology Co Ltd 16 8 Appearance...

Reviews: