Before installing this fireplace thoroughly assess the packaging and it’s contents (including the unit, 

flue components, grates, baffle plates, ceiling ring, etc) to ensure all items are accounted for and that 

any damage or defects caused by transport/handling are immediately reported to your authorised 

Cheminées

 

Philippe

 dealer

 

»

Check  the  installation  site  in  advance  and  remove  all  flammable  materials  or  those  which  have  the 

potential to be damaged by heat from the area where the fireplace will be installed. All combustible 

material should be replaced and/or shielded with non-combustible material or maintain a safe clearance 

as per pages 11-18 of this manual if installed freestanding or 19-24 if installed inbuilt 

 

»

Ensure the correct base underneath the fireplace is used including the minimum size and thickness, refer 

to page 8 for a list of recommended base materials. Check that the floor is capable of safely bearing the 

weight and if necessary put in a weight distribution plate or take other necessary measures 

 

»

Due  to  the  weight  of  each  fireplace  care  must  be  taken  when  maneuvering  the  unit.  We  strongly 

recommend mechanical equipment, as well as multiple professionals aiding with moving the unit into it’s 

intended location

 

»

Familarise yourself with section

 5. Mechanisms & Unit Assembly

 in this manual prior to proceeding. Due 

to the size of some units, the gather, lift door mechanisms, and/or dampers will need to be installed prior 

to the installation of the flue system. Please also refer to this section for the final fitting of the backplate, 

baffle plate, ash retainer and grates

 

»

When installing the unit inbuilt, ventilation grills are required at the top and bottom of the cavity to assist 

in natural convection and for the release of heated air into the room. Refer to pages 20-23 for minimum 

sizes and placement of grilles

 

»

When installing the fireplace inbuilt, an inspection hatch or trap door it recommended. This will allow for 

easy access to the unit when performing any necessary inspection, maintenance and/or repairs 

 

»

Do 

NOT

 use combustible material (including Gyprock Fyrechek OR a timber frame) underneath, near or 

around this fireplace

PREPARATION OF THE FIREPLACE

BALANCING AIR PRESSURE: TIGHTLY SEALED HOMES, MECHANICAL FANS & DOWNDRAFT

All fireplaces require constant air flow when in use, however due to the tightly sealed nature of 

certain homes it may prove difficult to achieve a continuous replenishment of fresh air for the fire to 

burn effectively. Mechanical fans (including range hoods, ceiling fans, return air vents including AC 

ducts, and overhead extractor fans) which are located within the same space as the fireplace, can 

also create negative pressure and compromise the operation of the unit.

If this occurs, the introduction of fresh air is recommended. This could take the form of a vent 

installed on an external wall where the fireplace will be situated. Depending on the installation type, 

it should either be placed directly inside the inbuilt fireplace cavity or as near to the freestanding 

fireplace as possible. The surface area of this air intake should be a minimum of 360cm2 (for 

example a vent 400mm x 90mm in size).

Termination of the flue in a high pressure zone such as on the downstream side of a nearby obstruction 

to airflow. For example; trees, hills, adjacent buildings or parts of the building where the unit is installed 

may also prove to cause downdraught conditions 

 (AS/NZS 2918:2018 extract), 

in this case refer to page 37

Summary of Contents for RADIANTE 873

Page 1: ...The Original Home Of Chemin es Philippe Australia since 1982 WARMTH FROM FRANCE BY WIGNELLS OF MELBOURNE RADIANTE 873 INSTALLATION USER MANUAL...

Page 2: ...o Australian emissions efficiency and safety standards Please take a moment to read over this manual including our operations and maintenance guide to ensure you get the best performance and enjoyment...

Page 3: ...URATIONS 18 4 INBUILT 4 1 STEP BY STEP INSTALL GUIDE 20 4 2 BASE HEARTH MANTEL SHELF DIMENSIONS 21 4 3 INBUILT CAVITY DIMENSIONS 22 4 4 DEFLECTOR PLATE GRILLS 23 4 5 FLUE COMPONENTS OVERVIEW 24 5 MECH...

Page 4: ...manual alongside the requirements of Australian New Zealand Standards AS NZS 2918 2018 The installation techniques handling and use of the product are beyond our control Therefore Chemin es Philippe...

Page 5: ...OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE Please read through this manual carefully prior to installing or using this fireplace Each of our fireplaces should be installed in accordance with...

Page 6: ...stalling the unit inbuilt ventilation grills are required at the top and bottom of the cavity to assist in natural convection and for the release of heated air into the room Refer to pages 20 23 for m...

Page 7: ...the top of the fireplace gather to the cowl A minimum 50mm clearance around the triple skin flue is to be maintained from the outer casing to any combustible surface A minimum 920mm clearance is to be...

Page 8: ...the fireplace base and hearth The purchaser should check with the base and hearth supplier that the material being used underneath and in front of the fireplace is suitable for extreme heat The base a...

Page 9: ...ONS SPECIFICATIONS 2 1 CHEMIN ES PHILIPPE RADIANTE 873 10 09 PLEASE NOTE Due to the handmade nature of our fireplaces there maybe a slight variance factor of 1 2mm across all unit dimensions and 5kg i...

Page 10: ...4013 2014 AS NZS2918 2018 and is recommended to be used with hardwood only HEATING CAPACITY Up to 340sqm MAXIMUM AVG HEAT OUTPUT 15kW FIREBOX MATERIAL Cast Iron LOG LENGTH Up to 50cm FLUE SIZE 9 11 1...

Page 11: ...3 4 SKAMOTEC WALL GUIDELINES 15 3 5 SKAMTOEC WALL VENTILATION 16 3 6 FLUE COMPONENTS OVERVIEW 17 3 7 FLUE SYSTEM CONFIGURATIONS 18 11 PLEASE NOTE All diagrams in this manual are for illustration purp...

Page 12: ...including charcoal painted stainless steel flues must be joined using stainless steel pop rivets and must be installed crimp end DOWN All galvanised second and third outer casing must be installed cr...

Page 13: ...1850mm x DEPTH As per above B x THICKNESS 50mm For a list of recommended materials and thicknesses refer to page 8 MINIMUM HEIGHT OF UNIT A 149mm A 150mm A 200mm A 300mm A 400mm A 500mm MINIMUM HEART...

Page 14: ...mm 1200mm Hearth Combustible Wall Combustible Wall Brick Hebel Brick Hebel A minimum 110mm solid brick hebel thick wall should extend a minimum height of 2200mm from the hearth when using a triple ski...

Page 15: ...d the cavity must be either ventilated at the top and bottom by using a minimum 25mm air gap that must extend the full width of the board or alternatively using metal vents vermin proof if on an exter...

Page 16: ...N CONFIGURATIONS WHEN USING 50MM BATTERNS SEE PAGE 14 The 25mm top and bottom air gap must extend the full width of the Skamotec cavity and can be left open to create a shadow line effect or alternati...

Page 17: ...Triple Skin Flue 900mm 13 Split Ring Charcoal 6 7 5 1 3 6 7 9 13 Cover Cone 9 Anti Down Draught Cowl 9 Flue Adaptor Charcoal 9 11 13 Default Triple Skin Flue 900mm Charcoal 2 x 9 11 13 Triple Skin Flu...

Page 18: ...ling and roof space 5 Flat ceiling with roof space and offset 6 Freestanding with chimney offset 7 External wall penetration 8 Double storey with single storey penetration 1 Flat ceiling with roof spa...

Page 19: ...ONS 21 4 3 INBUILT CAVITY DIMENSIONS 22 4 4 DEFLECTOR PLATE GRILLS 23 4 5 FLUE COMPONENTS OVERVIEW 24 19 PLEASE NOTE All diagrams in this manual are for illustration purposes only DO NOT scale from an...

Page 20: ...coverage Ensure the rockwool blanket is installed firmly to the inner sides of the enclosure and around the triple skin flue Ensure the slots of the starter triple are approx 100mm above the top of t...

Page 21: ...WIDTH 1850mm x DEPTH As per above x THICKNESS 50mm COMBUSTIBLE MANTEL SHELF SIDES Min 1000mm above and 300mm either side of unit For a list of recommended materials and thicknesses refer to page 8 MI...

Page 22: ...take on either side of the bottom of the cavity minimum size grilles 9cm x 40cm and should be in line with the base of the fireplace Outtake Size The same size on either side is required for the top a...

Page 23: ...ate then the triple skin starter flue if partial masonry or remaining single skin flue if fully masonry is to be installed above the plate Ventilation grills consisting of one large grill in front or...

Page 24: ...arter Triple Skin Flue 900mm 3 x 9 11 13 Triple Skin Flue 900mm 9 13 Cover Cone 6 9 Anti Down Draught Cowl 4 5 METER 9 FULL MASONRY FLUE KIT 2 1 3 4 5 9 Flue Adaptor 9 Starter Flue With Gussets 900mm...

Page 25: ...5 MECHANISMS UNIT ASSEMBLY 5 1 MECHANISM GUIDE 26 5 2 PARTS DAMPER ASSEMBLY 27 5 3 BACK PLATE BAFFLE PLATE GRATE ASSEMBLY 28 25...

Page 26: ...er closed it is not recommended to use the unit with the damper closed for extended periods of time D Damper opened LOCATION OF MECHANISMS PRIMARY AIR DAMPER CONTROLS OPEN CLOSE DOOR OPENING MECHANISM...

Page 27: ...oving the damper remove the baffle take care to hold the decorative back plate of the unit to avoid it falling then put the damper into the open vertical position 2 Raise the damper following the arro...

Page 28: ...h retainer covers on the left and right of the firebox 4 Place the front ash retainer into position 5 Place the left and right grates into the base of the firebox 6 Insert the ash pan IMPORTANT ENSURE...

Page 29: ...6 OPERATION 6 1 BEFORE FIRST IGNITION 30 6 2 RECOMMENDED FIRE WOOD 31 6 3 HOW TO LIGHT BURN SAFELY 32 33 6 4 WARNINGS LABELS 34 29...

Page 30: ...ances of smoke being blown back It is NOT recommended to use the unit with the door open for prolonged and continuous periods of time Never leave the door open unsupervised With the door closed Openin...

Page 31: ...at use large numbers of small logs eg 6 to 8 logs of 6cm in diameter on a good bed of embers For a longer lasting fire use larger diameter logs eg 3 logs of 13 to 15 cm diameter on a medium bed of emb...

Page 32: ...d front to back The second pieces should be slightly smaller in size and positioned side to side 2 Then follow the same cross section method for the kindling 3 Firestarters should then be evenly posit...

Page 33: ...time at a very slow burn rate with vents and damper fully closed is not recommended especially at the start and end of winter and when the temperature rises as this can cause deposits of soot and tar...

Page 34: ...replace door and call the fire brigade WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT US...

Page 35: ...7 MAINTENANCE 7 1 SERVICING GUIDE 36 7 2 TROUBLE SHOOTING 37 7 3 SPARE PARTS 38 35...

Page 36: ...ts equipped with a perforated grille on the outside clean this with a vacuum cleaner to avoid the build up of dust in the perforations which would reduce convection air circulation Regularly empty the...

Page 37: ...temperatures are causing low flue gas temperatures Have your fireplace checked by an authorised service agent Lack of heat The fire smoulders or goes out Try and light your fire using cut or smaller...

Page 38: ...number which can be found on the identification plate on the base of the unit on the base of the ash pan chamber Only use spare parts in particular the replacement of glass should only be sourced and...

Page 39: ...8 WARRANTY 8 1 WARRANTY POLICY EXTENDED WARRANTY 40 8 2 INSTALLER CHECKLIST FORM 41 39...

Page 40: ...e therefore guaranteed for one year as per the table below The window panes can resist temperatures of around 750 So any breakage can only be caused by impact during use or handling and cannot be exch...

Page 41: ...packaging including any flammable material has been removed 6 The user has been shown the Mechanisms Operation Maintenance guide 7 The user has been advised to cure the firebox initially with 10 small...

Page 42: ...CHEMIN ES PHILIPPE AUSTRALIA BY WIGNELLS OF MELBOURNE 430 Johnston St Abbotsford VIC 3067 180 Whitehorse Rd Blackburn VIC 3130 03 9417 3315 WWW CHEMPHILAUST COM AU...

Reviews: