OPTION A:
25MM TOP & BOTTOM AIR GAP
OPTION B:
CONCEALED EXTERNAL VENTS
OPTION C:
CONCEALED INTERNAL VENTS
SKAMOTEC WALL VENTILATION CONFIGURATIONS (WHEN USING 50MM BATTERNS, SEE PAGE 14)
The 25mm top and bottom air gap must extend the full width of the Skamotec cavity and can be left open
to create a shadow line effect, or alternatively can be faced with a metal grill/vent
The minimum concealed surface area of vent is one 720cm2 top (9cm x 80cm) at the top and bottom or 2 x
360cm2 (9cm x 40cm) top and bottom as illustrated