36414TCB3CD (5-17) 

15 

PARTS LIST  

 

 

 

 

 

 

 

 

       36414TCB3CD 

TANK GROUP 

Summary of Contents for 36414TCB3CD

Page 1: ...tractor Manufactured by Kleenrite KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U S A FAX 1 559 673 5725 CUSTOMER SERVICE 1 800 241 4865 Operator and Parts Manual Powerbase 10 CARPET AND UPHOLSTERY CLEA...

Page 2: ...rer its service agent or similarly qualified persons in order to avoid a hazard Do not run machine over cord Keep cord away from heated surfaces Do not unplug machine by pulling on cord Do not stretch...

Page 3: ...imilaire afin d viter un danger Ne pas passer de machine sur cordon Gardez le cordon des surfaces chaudes Ne pas d brancher la machine en tirant sur le cordon Ne pas tirer le cordon ou g rer les extr...

Page 4: ...be ordered by phone or mail from any authorized parts and service center distributor or directly from Kleenrite This machine will provide excellent service However the best results will be obtained at...

Page 5: ...vicing machine Unplug cord from wall outlet Avoid moving parts Do not wear loose jackets shirts or sleeves Use manufacturer supplied or approved replacement parts Have service performed by authorized...

Page 6: ...Pump Switch 14 Recovery Tank Drain Handle 15 Empty Out Nozzle 16 Recovery Tank Drain Outlet 17 Power Cords MACHINE SETUP 1 Carefully check carton for signs of damage Report damages at once to carrier...

Page 7: ...breakers on the switch panel 4 Turn on heater for 6 to 8 minutes to warm heat exchanger When red lights go off the heat exchanger is at full temperature Figure 4 CLEANING CARPETS 1 Activate remaining...

Page 8: ...of solution hose 2 Place empty out nozzle over a bucket and turn on pump until all the solution has been pumped from solution tank Figure 10 3 Replace empty out nozzle to its storage location FREEZE P...

Page 9: ...f the machine and insert a 5 64 Allen wrench into the pressure adjusting screw of the pump as indicated by the arrow in Figure 13 If the pump pulsates on and off during solution flow the pump should b...

Page 10: ...ers 3 Inspect cord and cord grip for damage Replace immediately if damaged 4 Lubricate metal shaft on recovery tank drain with water resistant oil 5 Lubricate female hose couplers with lightweight oil...

Page 11: ...e Center Faulty vacuum switch Contact Service Center Defective vacuum motor Contact Service Center Worn carbon brushes Contact Service Center Poor solution pick up Recovery tank drain valve open Close...

Page 12: ...0 gal SOLUTION PUMP 220 V 6 8 bar 100psi 4 A VACUUM MOTOR 220 V 6A 1380W HEATERS MAIN 220V 6 1A 1800W AUX 220V 1 6A 500W SEALED WATER LIFT CFM 3581 mm 141 in 3 76CMM 132 8 CFM TOTAL POWER CONSUMPTION...

Page 13: ...36414TCB3CD 5 17 13 ELECTRICAL DIAGRAM 36414TCB3CD 240 V WIRING DIAGRAM...

Page 14: ...36414TCB3CD 5 17 14 ELECTRICAL DIAGRAM 36414TCB3CD 240 V WIRING DIAGRAM...

Page 15: ...36414TCB3CD 5 17 15 PARTS LIST 36414TCB3CD TANK GROUP...

Page 16: ...T OFF 1 K 05 8 THERMAL CRCT BRKR EDGE 13AMP 2 Part Description Qty K 13 3 LIGHT RED ROUND 2 K 16 85A NUT NYLON BELL MOUTH 13 10MM 2 K 21WGRY SWITCH SPST WTR RESIS GRY 4 K 28 05 TIE WIRE NYLON 10 SCREW...

Page 17: ...36414TCB3CD 5 17 17 PARTS LIST 36414TCB3CD BASE GROUP...

Page 18: ...5 O RING VITON 4 OR FIT90D 3 J 02 7 CAST ALUM COIL NEX GEN 1 J 47 5CE ROTO BLACK THERMOSTAT COVER CE 1 K 12 28 HEATER CART 900 500 240V 10LONG 2 K 17 4 CLAMP NYLON CABLE 1 4 4 K 23 24CE THRMST 210 SPS...

Page 19: ...36414TCB3CD 5 17 19 PARTS LIST 36414TCB3CD HANDLE GROUP...

Page 20: ...UT OFF 1 K 05 8 THERMAL CRCT BRKR EDGE 13AMP 2 Part Description Qty K 13 3 LIGHT RED ROUND 2 K 16 85A NUT NYLON BELL MOUTH 13 10MM 2 K 21WGRY SWITCH SPST WTR RESIS GRY 4 K 28 05 TIE WIRE NYLON 10 SCRE...

Page 21: ...redit has been established prior to the request the part will be shipped on an Open Account basis part plus freight A Return Authorization must be requested at the time of order so that the suspected...

Page 22: ...ll immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Damage caused by plu...

Page 23: ...ill immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Damage caused by pl...

Reviews: