Electric Induction hobs Chef’s EH-IH545
24
EEPROM fault
FH
App. off
-------
Microcontroller A/D converter
multiplexer fault
FJ
App. off
When the fault
dissapears
Ambient Light fault
FL
App. off
When satisfactory
ambient lighting is
detected
Microcontroller A/D converter
conversion fault
FU
App. off
When the fault
dissapears
Communication fault
F5
Heater/s off
When the fault
dissapears
Heater temperature sensor short-
circuit
F1
Heater/s off
When the fault
dissapears
Heater temperature sensor open-
circuit
F2
Heater/s off
When the fault
dissapears
Heater temperature sensor error 1
F7
Heater/s off
When the fault
dissapears
Heater temperature sensor error 2
F8
Heater/s off
When the fault
dissapears
Heater voltage fault
F9
Heater/s off
When the fault
dissapears
Power unit temperature sensor
short-circuit
F3
Heater/s off
When the fault
issapears
Power unit temperature sensor
open-circuit
F4
Heater/s off
When the fault
dissapears
Mains zero crossing loss
F6
Heater/s off
When the fault
dissapears