DESCRIPTION OF YOUR RANGEHOOD

1

2

Flue pipe to be sourced locally

3

4

5

6

7

Components list

1. Screws x 2

2. Telescopic flue cover set

3. Upper flue cover mounting bracket

4. Lower flue cover mounting bracket

5.  Flue transition duct

6. Main body and fan housing assembly

7. Grease filters

Additional items required for installation

• Fixings required to attach rangehood body and 

anti tilt points.

• Fixings required to attach flue cover mounting 

brackets to the wall.

• Duct tape or cable ties. 

Technical specifications

The manufacturer reserves the right to effect any 

technological improvement or modification without  

prior notice.

Fig. 3

User manual_CS910CS

• Flue pipe. 

4

Height

69-113.5cm

Width

90cm

Depth

50cm

Maximum absorbedpower

330W

Lighting

2 x 50W Halogen

Outlet diameter

150mm

Electrical connection

220-240V, 50Hz

MODEL

CS910CS

69-113.5cm

90cm
50cm

330W

2 x 3.5W LED

150mm

220-240V, 50Hz

CRC914SB/CRC914DB

 

 

Summary of Contents for CRC914DB

Page 1: ...RANGEHOOD User Manual CS910CS CRC914SB CRC914DB...

Page 2: ...MATION IMPORTANT CHECK FOR ANY DAMAGES OR MARKS If you find the rangehood is damaged or marked you must report it within 7 days if you wish to claim for damage marks under the manufacturers warranty T...

Page 3: ...ppliance which has been manufactured and tested to comply with Australian and New Zealand Standard AS NZS 60335 2 31 Meanings of symbols used in this manual are shown below CAUTION This symbol indicat...

Page 4: ...ach rangehood body and anti tilt points Fixings required to attach flue cover mounting brackets to the wall Duct tape or cable ties Technical specifications The manufacturer reserves the right to effe...

Page 5: ...OOD DIMENSIONS 56mm 500mm 320mm 900mm 1135mm maximum 690mm minimum 290mm 538mm Fig 4 150mm NOTE The fan housing flue transition duct is 150mm in diameter See page 11 for optional ducting accessories F...

Page 6: ...mm GAS ELECTRIC Ceiling Flue cover wall mounting brackets Rangehood mounting points Anti tilt fixing points Hood base Min 600mm Max 800mm Min 650mm Max 800mm 286mm 559mm 36mm PRE INSTALLATION Before i...

Page 7: ...ded in recirculation kit AR910RK to prevent odours being emitted back into the room 6b Ducted mode Fig 10 The rangehood can be connected with a 150mm diameter non combustible flue pipe rigid or flexib...

Page 8: ...rds of local building gas and electrical authorities Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the rangehood Installatio...

Page 9: ...nded intervals Failure to do so will cause grease deposits that could cause a fire Removing the metal grease filters Push the grease filter towards the back of the unit and then pull it down and out H...

Page 10: ...fan speed has been selected The cooker hood is not working Check that the fan speed is set high enough for the task The grease filters are clean The kitchen is adequately vented to allow the entry of...

Page 11: ...G Bond Roof Cowl AR150F 150mm G Bond Flue 1200mm AR150WV 150mm Wall Vent duct AR910RK Recirculating Kit 150 120mm reducer T piece carbon filters AR610CF Replacement carbon filter AR610FS Stainless st...

Page 12: ...notes 12...

Page 13: ...13...

Page 14: ...notes 14...

Page 15: ...used by i negligence or accident ii misuse or abuse including failure to properly maintain or service iii improper negligent or faulty servicing or repair works done by anyone other than an Electrolux...

Page 16: ...r further information on all Chef appliances or to obtain detailed dimension and installation information call into your Retailer phone or email our Customer Care team or visit our website Australia p...

Reviews: