C
HEETAH
864XR
V
IDEO
M
ATRIX
S
WITCHER
Publication 81-9059-0595-0, Rev. C
October 2010
Proprietary Information of
PESA
3-21
Frame Control connectors allow communication with the frame controller CCA in the 864XR chassis
and System Control connectors allow communication with the system controller CCA in the 864XR
chassis.
Two LED indicators associated with each rear-panel connector provide a visual status of link activity.
Refer to Figure 3-19 and Table 3-7.
All communication activities between frame controller and system controller CCAs and other external
components of a control system follow the standard Ethernet protocol. Ethernet configuration options
are discussed in Appendix A of this manual.
ALARM
SYSTEM CONTROL
ALARM
RCP PANEL PORT
4
3
2
1
NETWORK
OUTPUT
MONITOR
AUX FRAME CTRL
SLOT B
3
SLOT A
REFERENCE
1
1
2
4
2
FRAME
ALARM
FRAME
CONTROL
3
4
PRC LOOP
COM 1
COM 2
COM 4
COM 3 / PRC
SYSTEM
CONTROL
NETWORK
FRAME
CONTROL
SYSTEM
CONTROL
SLOT
A
SLOT
B
Figure 3-18 - Network Connectors
Figure 3-19 - Ethernet Connector
Table 3-7 - Ethernet LED Indicators
LNK
ON = Ethernet LINK established
100M
ON = The Ethernet connection speed is 100Mb/s
OFF = The Ethernet connection speed is 10Mb/s
To connect the cards to the network, do the following:
1. Set the IP address, Subnet mask, Gateway address, and Trap address on Matrix Frame
Controller to addresses approved by the Network Administrator.
2. Using a straight through RJ-45 Ethernet cable, connect the Ethernet jacks to a 10/100BASE-T
hub or switch on the TCP/IP network.
Green LED
Yellow LED