background image

[C

la

s

s

if

ic

a

ti

o

n

:

P

ro

te

c

te

d

]

25 February 2021

QUANTUM SMART-1

6000-L/6000-XL

APPLIANCES

REPLACING MEMORY

Summary of Contents for QUANTUM SMART-1 6000-L

Page 1: ... Classification Protected 25 February 2021 QUANTUM SMART 1 6000 L 6000 XL APPLIANCES REPLACING MEMORY ...

Page 2: ...precaution has been taken in the preparation of this book Check Point assumes no responsibility for errors or omissions This publication and features described herein are subject to change without notice RESTRICTED RIGHTS LEGEND Use duplication or disclosure by the government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause...

Page 3: ...ng attacks Certifications For third party independent certification of Check Point products see the Check Point Certifications page Check Point Quantum Smart 1 6000 L 6000 XL Appliances Replacing Memory For more about this release see the home page Latest Version of this Document in English Download the latest version of this document in PDF format Feedback Check Point is engaged in a continuous e...

Page 4: ...for Smart 1 6000 L Base 8 Upgrading the Configuration from 96GB to 192GB 9 Smart 1 6000 XL DIMM Configuration 10 Default Configuration for Smart 1 6000 XL Base 10 Upgrading the Configuration from 192GB to 384GB 11 Procedure 12 Preparing the Appliance 12 Removing the Cooling Air Shroud 14 Removing a DIMM 14 Installing a DIMM 14 Installing the Cooling Air Shroud 15 Reassembling the Appliance 16 Veri...

Page 5: ...atic mat and antistatic strap on your wrist while working on components inside the appliance n To ensure proper operation and cooling all bays in the appliance and cooling fans must be always populated with a component n For proper heat dissipation and cooling Smart 1 6000 L 6000 XL appliances contain a cooling air shroud that covers the empty memory module sockets that are not occupied For more i...

Page 6: ...dware Components Quantum Smart 1 6000 L 6000 XL Appliances Replacing Memory 6 Hardware Components Item Description 1 Front panel 2 24 Memory module sockets located under the cooling air shroud 3 Rear panel ...

Page 7: ... 6000 L Plus Smart 1 6000 XL Base Smart 1 6000 XL Plus 96GB 192GB 192GB 384GB The memory sockets have black and white colored ejectors In the appliance configuration diagrams note that n The view shown is always from the top n The front panel of the appliance is always at the bottom of the diagram Item Description Memory sockets with DIMMs installed Empty memory sockets Important The cooling air s...

Page 8: ...memory socket numbers shown in the configuration diagrams are marked on the cooling shroud and align with the respective memory sockets Default Configuration for Smart 1 6000 L Base Top View front of the Security Management Appliance is at the bottom of the diagram Best Practice We recommend that you keep the DIMMs in the socket numbers as specified in the Default Configuration diagram Changing th...

Page 9: ...92GB To upgrade from To upgrade to Use DIMMs Procedure Sockets 96GB 192GB 24x8GB Install an additional twelve 8GB DIMMs See the Upgraded Configuration diagram for the socket numbers 24 out of 24 Upgraded Configuration from 96GB to 192GB in Smart 1 6000 L Top View front of the Security Management Appliance is at the bottom of the diagram ...

Page 10: ...he memory socket numbers shown in the configuration diagrams are marked on the cooling shroud and align with the respective memory sockets Default Configuration for Smart 1 6000 XL Base Top View front of the Security Management Appliance is at the bottom of the diagram Best Practice We recommend that you keep the DIMMs in the socket numbers as specified in the Default Configuration diagram Changin...

Page 11: ...4GB To upgrade from To upgrade to Use DIMMs Procedure Sockets 192GB 384GB 24x16GB Install an additional twelve 16GB DIMMs See the Upgraded Configuration diagram for the socket numbers 24 out of 24 Upgraded Configuration from 192GB to 384GB in Smart 1 6000 XL Top View front of the Security Management Appliance is at the bottom of the diagram ...

Page 12: ... configuration Preparing the Appliance To prepare the appliance 1 Make sure to follow the Safety Instructions on page 5 2 Shut down the appliance n In Gaia Portal Go to Maintenance Shut Down and click Halt n In Gaia Clish Run halt 3 Open the retention strap that secures the power cables to the PSUs 4 If AC PSUs are installed in the appliance Disconnect the power cables from the AC PSUs 5 If DC PSU...

Page 13: ...grounding strap on your wrist and attach the other end to a grounding point 9 Remove the appliance cover a Using a flat or a Phillips head screwdriver rotate the latch release lock counter clockwise to the unlocked position b Lift the latch c Slide the cover back The tabs on the cover should disengage from the guide slots on the appliance d Hold the cover on both sides and lift the cover away from...

Page 14: ...avoid touching the components or metallic contacts on the DIMM To remove a DIMM 1 Locate the appropriate memory socket Caution Handle each DIMM only by the card edges ensuring not to touch the middle of the DIMM or metallic contacts 2 Push the ejectors outward on both ends of the memory socket to release from the socket 3 Lift and remove the DIMM from the system Installing a DIMM To install a DIMM...

Page 15: ...sert the DIMM in the socket Caution Do not apply pressure at the center of the DIMM apply pressure at both ends of the DIMM evenly Note The memory socket has an alignment key that enables you to install the DIMM in the socket in only one orientation 4 Press the DIMM with your thumbs until the socket levers firmly click into place Installing the Cooling Air Shroud 1 Align the tabs on the air shroud...

Page 16: ...rward the tabs on the cover should engage with the guide slots on the appliance The latch should lock into place 5 Use a flat or Phillips head screwdriver to rotate the latch release lock clockwise to the locked position Item Description 1 Latch release lock 2 Latch 3 Cover 6 Install the appliance into the rack See the Installing the Quantum Smart 1 6000 L 6000 XL Telescopic Rails booklet for illu...

Page 17: ...tton on the front panel to turn on the Security Management Appliance Verifying the Memory Configuration To make sure that the memory configuration is correct 1 In the CLI enter Expert mode 2 Run free g Example output from a Smart 1 6000 L Base Security Management Appliance with 96GB of memory Note The amount of installed memory is shown in the row named Mem under the column named total In the abov...