16000 Appliances Hardware
16000 Appliances Getting Started Guide | 43
Example:
To recover from a BIOS failure, see
or contact
. The appliance is fully
functional until the BIOS recovery is completed. Note that it can take a few minutes for it to boot in BIOS
recovery mode.
PSU Configuration and Monitoring
These are the supported PSU configurations for the appliance models and PSU types:
PSU Type
16000/16200 Base
16000/16200 Plus
16000 Turbo
16600HS
AC PSU
1 AC PSU
1 Dummy filler
2 AC PSUs
2 AC PSUs
2 AC PSUs
DC PSU
2 DC PSUs
2 DC PSUs
2 DC PSUs
2 DC PSUs
Important
- All PSUs on an appliance must be of the same type, either all AC or all DC.
When a PSU is functioning correctly: the PSU LED is green, the Alert LED is not blinking due to a PSU issue
(might still be blinking due to other errors), and there is no SNMP alarm.
When a PSU is not functioning correctly: the PSU LED is amber, the Alert LED is blinking due to a PSU
issue, and an SNMP alarm is sent.
To monitor the PSUs through the CLI:
1.
Connect to the command line on the appliance.
2.
Log in to
Gaia Clish
.
3.
Run:
show sysenv ps
Sample output for a 16000 Turbo appliance:
Where: