background image

- 1 -

Table of Contents

1.0   Introduction

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

2

1.1  Package Contents

2.0   Safety Instructions

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

2

3.0   Overview

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

3

4.0   Assembly and Connection

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

4

4.1   Typical Connection Examples

5.0   Operation

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

6

6.0 Flash 

Tube 

Replacement

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

7.0 Specifications

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

8

8.0 Warranty

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0

inside back cover

- 8 -

General

Range 

0 to 12,500 FPM (flashes per minute)

Power Input 

15 to 28 VDC / 12 W
DIN 41524 5-pin standard connector
Universal power supply available

External Trigger  Input

3 to 30 V / max. 5 mA
(potential free optocoupler)
DIN 41524 5pin standard connector
Uout = 24 V max. 200 mA

Housing Material 

Aluminum

Size 

6.0" x 5.1" x 4.4" 

(150 x 130 x 112mm)

Weight 

870 g

Ambient Temp

32 to 104 °F

(0° to 40 °C) 

Storage Temp 

–13 to 158 °F 

(–25° to 70 °C) 

Humidity 

Max. 95 % not condensed

Flash Tube  Parameters

Lifetime 

> 200,000,000 flashes (@ 6,000 FPM)

Flash Duration

< 5 µs

Light Emission Flash 

10 Mega-Lux /12"

(30 cm)

Light Emission

500 Lux / 30 cm / 12" (@ 6,000 FPM)

Illumination Area 

7.8" x 12" 

(20 x 30 cm)

Flash Color 

6,000 – 6,500 K

Flash Energy 

600 mJ @ 1,200 FPM

Certifications

EMV/EM
C 2004/108/EC

EN 61010:2001
2006/95/EC

7.0 S

PECIFICATIONS

Summary of Contents for LS-5-12000

Page 1: ...igger Input 3 to 30 V max 5 mA potential free optocoupler DIN 41524 5pin standard connector Uout 24 V max 200 mA Housing Material Aluminum Size 6 0 x 5 1 x 4 4 150 x 130 x 112mm Weight 870 g Ambient Temp 32 to 104 F 0 to 40 C Storage Temp 13 to 158 F 25 to 70 C Humidity Max 95 not condensed Flash Tube Parameters Lifetime 200 000 000 flashes 6 000 FPM Flash Duration 5 µs Light Emission Flash 10 Meg...

Page 2: ...rge before replacing the flash tube Any service beyond flash tube replacement is not recommended Do not look directly at the emitted light it can damage your eyes It may also trigger seizures in people with photosensitive epilepsy Flash tubes are filled with high pressure gas When handling the flash tube always always wear safety glasses and protective gloves Do not allow inflammable liquids and w...

Page 3: ...open cable connection for external equipment LS 5 RCU Control Unit not shown 6 5 0 OPERATION 1 Position the stationary stroboscope and connect the trigger input signal and supply voltage to the sockets as outlined in Section 4 0 2 Switch the stroboscope on The red LED will light indicating that the unit is ready for use 2 As soon as the trigger signal is applied the strobe will start to flash with...

Page 4: ...connect the trigger signal CAUTION Do not trigger the stroboscope with signals above 12 500 FPM 4 1 Typical connection examples Please take connection examples from Figures 2 to 5 Note that you will need optional accessories for some of the examples stationary strobo scope AC Adapter sensor etc Fig 2 Trigger signal and supply voltage from external equipment Fig 1 Fig 2 5 Fig 3 Trigger signal from ...

Page 5: ... RESULTING FROM THE USE OF SUPPLIED EQUIPMENT WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE UPON OR AFTER REPLACEMENT OR REPAIR AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not ap...

Page 6: ...TIC E Q U I P M E N T C O I N C 600 Oakland Ave Cedarhurst NY 11516 U S A TEL 516 295 4300 FAX 516 295 4399 CHECK LINE INSTRUMENTS LS 5 12000 LINEAR STROBOSCOPE Operating Instructions CHECK LINE BY ELECTROMATIC ...

Reviews: