background image

ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the
original purchaser that this product is of merchantable quality and confirms 
in kind and quality with the descriptions and specifications thereof. Product
failure or malfunction arising out of any defect in workmanship or material in the
product existing at the time of delivery thereof which manifests itself within one
year from the sale of such product, shall be remedied by repair or replacement of
such product, at ELECTROMATIC’s option, except where unauthorized repair,
disassembly, tampering, abuse or misapplication has taken place, as determined
by ELECTROMATIC. All returns for warranty or non-warranty repairs and/or
replacement must be authorized by ELECTROMATIC, in advance, with all
repacking and shipping expenses to the address below to be borne by the 
purchaser.

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE
WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY
PARTICULAR PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT
BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE,
OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED
EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED
BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER
OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER’S OR 
SUPPLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE.

Some State jurisdictions or States do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation may not apply to
you. The duration of any implied warranty, including, without limitation, fitness
for any particular purpose and merchantability with respect to this product, is 
limited to the duration of the foregoing warranty. Some states do not allow
limitations on how long an implied warranty lasts but, not withstanding, this 
warranty, in the absence of such limitations, shall extend for one year from the
date of invoice.

ELECTROMATIC Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399 

Every precaution has been taken in the preparation of this manual. Electromatic
Equipment Co., Inc., assumes no responsibility for errors or omissions. Neither is
any liability assumed for damages resulting from the use of information contained
herein. Any brand or product names mentioned herein are used for identification
purposes only, and are trademarks or registered trademarks of their respective
holders.

9.0

W

ARRANTY

Summary of Contents for DT-725

Page 1: ...es Per Minute Accuracy 0 02 of reading Resolution 0 1 40 0 4 999 9 FPM 0 2 5 000 0 7 999 8 FPM 0 5 8 000 0 9 999 5 FPM 1 0 10 000 0 12 500 0 FPM Display 5 Digit LED 0 3 8mm height Rate Divide by 2 Multiply by 2 Update Time Ext mode varies with flashing rate Operating Time 1 hour when fully charged Model DT 725 Continuous Model DT 721 Flash Tube Power Live Xenon 10 W 100 million flashes Flash Durat...

Page 2: ...he rate slightly phase shif and is used for the same reason as above Input and Output Connectors Phonejack 3 5 mm Tip Signal Sleeve GND Power switch with lock option Power cord DT 721 only not shown 2 2 Kit Option A Kit option is offered which also includes a carrying case and spare flash tube at minimal additional cost Setter Input Output Connectors 7 7 0 FLASH TUBE REPLACEMENT When FPM reading i...

Page 3: ... When the time period between charges becomes increasingly shorter replace the battery 6 5 0 MEMORY When the strobe is turned off and on again at a later time it will start to flash at the previous displayed rate regardless if the setter has been moved or not 6 0 TRUE RPM All strobes give the illusion of stopped motion when flashing in submultiples of the true speed To obtain the correct rpm turn ...

Page 4: ... Pull power trigger switch and lock it When the ext phone jack is inserted in unit the strobe automatically switches from the internal mode to the external 3 The strobe will flash every time the sensor puts out a pulse Input signal requirements are listed below a 12 24 VDC thru a 3 wire NPN sensor Requires external power supply b 12 VDC thru a 2 wire proximity sensor Leakage Current 1 mA max Load ...

Page 5: ...OM THE USE OF SUPPLIED EQUIPMENT WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE UPON OR AFTER REPLACEMENT OR REPAIR AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you Th...

Page 6: ...TAL STROBOSCOPE TACHOMETER Operating Instructions CHECK LINE BY ELECTROMATIC Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net ...

Reviews: