background image

 

 

Electromatic Equipment Co., Inc. 

-16- 

NOTES 

 

Electromatic Equipment Co., Inc. 

-1- 

TABLE OF CONTENTS 

 
 
1.0 

Design of the device        ………………………………………………… 

 

2.0  

Measuring Procedure       ………………………………………………. 

 

3.0 

Calibration curves       ……………….………………………………..… 

 

4.0 

Menu level overview       ………………………………………………... 

 

5.0 

Keypad symbols       …………………………………………………….. 

 

6.0 

Changing batteries       ………………………………………………..… 

 

7.0 

Determination of the material moisture       …………………………… 

 

8.0 

Transfer saved data to the PC      ……………………………………… 

 

9.0 

Print saved data      ……………………………………………………… 

11 

 

10.0  Technical data      …………………………………………………….…. 

12 

 

11.0  Most common reasons for miss readings       ……….……………..… 

13 

 

12.0  Device maintenance instructions       ………………………………..… 

13 

 

13.0  Warranty       ……………………………………………………………… 

14 

 
 

Summary of Contents for BP1

Page 1: ...cedure 3 3 0 Calibration curves 5 4 0 Menu level overview 6 5 0 Keypad symbols 7 6 0 Changing batteries 8 7 0 Determination of the material moisture 8 8 0 Transfer saved data to the PC 9 9 0 Print saved data 11 10 0 Technical data 12 11 0 Most common reasons for miss readings 13 12 0 Device maintenance instructions 13 13 0 Warranty 14 ...

Page 2: ...nc 2 1 0 DESIGN OF THE DEVICE Batteries slot flipside Measuring chamber Optional PC interface Name of calibration Moisture content POWER button Filling assistance Change the calibration curve Electromatic Equipment Co Inc 15 NOTES ...

Page 3: ...s do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you The duration of any implied warranty including without limitation fitness for any particular purpose and merchantability with respect to this product is limited to the duration of the foregoing warranty Some states do not allow limitations on how long an implied warranty l...

Page 4: ...rage area usually creates condensed water which may lead to major measuring errors Not adjusted pellets Let your humimeter BP1 adjust to the surrounding temperature of the material for approximately half an hour A very high temperature difference has a negative effect on the stability of the measurement result Wrong calibration curve Before you measure your sample double check the correct selectio...

Page 5: ...ring range limits 280g wood pellet 280g 3 up to 20 250g spec pell 1 250g 3 up to 20 250g spec pell 2 250g 3 up to 20 250g spec pell 3 250g 3 up to 20 reference Explanation of the curves 280g wood pellet To analyze the moisture of Ø6 and Ø8 mm wood pellets with a maximum length of 30mm According to norm CEN TS 14961 If you do not want to measure wood pellets or wood pellets with smaller bulk densit...

Page 6: ...rial interface module in combination with Schaller thermo printer To print your saved logs connect the printer to the humimeter serial interface using the cable that was delivered with your device To switch on the printer press the ON OFF button If the printer is correctly switched on the green LED blinks regularly If it does not replace the batteries and try again Press the key until you reach th...

Page 7: ...ow the port number COM1 COMX You can find this setting in the device manager directory ports COM LTP See print screen below The shown port number in the device manager COMx in our example COM6 for the USBRS232 adapter has to be selected in the software humimeter LogMemorizer directory Extras Settings Device Close the dialog using the button OK Electromatic Equipment Co Inc 7 5 0 KEYPAD SYMBOLS Mea...

Page 8: ...ring results Each device includes a serial number and the guarantee stamp If those are broken no claims for guarantee can be made In case of a faulty device please contact Electromatic F x 100 Mn Mt Mn Electromatic Equipment Co Inc 9 8 0 TRANSFER SAVED DATA TO THE PC Only possible with humimeter serial interface module To send your saved logs to your PC connect the humimeter device to your PC usin...

Page 9: ...BP1 PELLET MOISTURE METER OPERATING INSTRUCTIONS Distributed by ABQ Industrial LP USA Tel 1 281 516 9292 888 275 5772 eFax 1 866 234 0451 Web https www abqindustrial net E mail info abqindustrial net ...

Reviews: