Battery Container Overview
ALPHA3D USER MANUAL
| 2019-06
P a g e | 33
4.2
Functional Specification
4.2.1
Orange Container Function
4.2.1.1
Orange Container Light Condition
When orange container is turn off, long-press switch button until buzzer sounds and display
screen shows battery information; Again, long-press switch button until buzzer sounds, and
orange container will turn off. If orange container is not used for a long time, it is
recommended to turn off it manually. Otherwise, it will turn off automatically after half hour
under light condition.
4.2.1.2
Orange Container Discharge Condition
The orange container will turn on automatically when it loads greater than 0.5A current and
the display screen will present battery information. Under load condition, the switch button
cannot work.
4.2.1.3
Orange Container Charge
The orange container is equipped with a 13.8V 7.2A battery charger for charge. It will turn on
automatically when it connects to charger with greater than 0.5A current and the display
screen will present battery information. Under charge condition, the switch button cannot
work. When charger light changes from red to green and charge current is 0A, it means the
battery is full charged.
4.2.1.4
Orange Container Communication
The orange container supports RS485 communication function which can transfer battery
information to controller unit and present under power-on condition.
4.2.1.5
Orange Container Low Voltage Alarm
Under power-on condition, the orange container will continuously alarm if voltage below
10.5V. Short press switch button to turn off sound after alarm.
4.2.1.6
Orange Container Overcurrent Protection
The orange container supports overcurrent protection function. If output port is short
connection or current is higher than 30A, the fuse will burn out. Change another 6*30mm 30A
glass fuse and the orange container will use normally.