AC SIDE (INVERTER)
Connect the instrument to the downstream side of the inverter and connect the instrument as indicated by
the "measurements connection diagram, single-phase inverter side (page 21)" or the "measurements
connection diagram, three-phase inverter side (page 25)".
In the FUNCTIONS MENU - MEASUREMENT, select MEASUREMENT ACQUISITION and place the cursor
on INVERTER.
Check the connections to the system and press ENTER to acquire the measurements (an “*” and the
flashing text CURRENT ACQUISITION... indicate that the operation is in progress).
To confirm the recording of the DC side and AC side measurements acquired, place the cursor on CONFIRM
MEASUREMENT and press ENTER (the text STORING MEASUREMENT... flashes to indicate that the
operation is in progress).
8.18 COMMUNICATION INTERFACE
The standard GREEN TEST FTV 100 has an RS232 interface (9-pin D-SUB), a USB interface, and enough
memory to store approximately 200 sets of measurement (one main measurement + secondary
measurements: voltage, current, power, atmospheric data, date, time, etc.).
The instrument includes a real-time clock for the date and the time.
The USB interface is used to process and transfer the stored data to a PC running GREEN REPORT
software.
8.18.1 RS232 INTERFACE - TECHNICAL CHARACTERISTICS
Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, no protocol
Rate: 38,400 bauds
8.18.2 USB INTERFACE - TECHNICAL CHARACTERISTICS
Protocol v.2.0. If no communication is detected, please contact our Customer Service for the installation of
the driver.
The USB interface is also used to update the internal microprogram of the instrument (contact us for more
information).
8.19 "GREEN REPORT" SOFTWARE
The GREEN REPORT software on the CD-ROM provided is used for the following operations:
♦
remote management;
♦
management of the measurements stored on the instrument;