22
3. CHARACTERISTICS
3.1. ENVIRONMENTAL CONDITIONS
Indoor use.
Operating range
‑10 °C to +55 °C and 10 % to 85% RH
Storage range
‑40 °C to +70 °C and 10 % to 90% RH
Degree of pollution
2
Altitude
< 2000 m
3.2. CONSTRUCTION SPECIFICATIONS
MN93 and MN93A
Dimensions (L x W x H) 135 x 51 x 30 mm
Cord
3,50 metres long
Weight
approx. 290 g
C193
Dimensions (L x W x H) 216 x 111 x 45 mm
Cord
3,50 metres long
Weight
approx. 690 g
PAC93
Dimensions (L x W x H) 236.5 x 97 x 44 mm
Cord
3,50 metres long
Weight
approx. 540 g
Battery life
120 hours with an alkaline battery
Amp
FLEX
TM
A193 450 mm
Dimensions (L x W x H) approx. 170 x 158 x 25 mm
Cord
3,50 metres long
Weight
approx. 220 g
Amp
FLEX
TM
A193 800 mm
Dimensions (L x W x H) approx. 280 x 265 x 25 mm
Cord
3,50 metres long
Weight
approx. 270 g
Protection index IP 40 for the clamps and IP 30 jaws open, according to IEC 60 529
(Ed. 92)
IP 65 for the AmpFLEX
TM
according to IEC 60 529 (Ed. 92)
IK 04 according to IEC 50102 (Ed. 95)
Drop test
According to IEC 61010‑1 (Ed. 2 of 2001)
3.3. CONFORMITY TO INTERNATIONAL STANDARDS
Electrical safety according to IEC 61010‑2‑032 (Ed. 2 of 2003).