Chauvet Vue III User Manual Download Page 1

 

Chauvet, 3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A.  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com

 

Vue™ III 

 

 

 
 
 
 
 
 

 

Snapshot 

Ok on Dimmer 

 

Outdoor OK 

 

Sound Activated 

 

DMX512 

Master/Slave 

115V/230V Switch 

 

Replaceable Fuse 

User Serviceable 

 

Duty Cycle 

 

 
 
 

USER MANUAL 

 

Summary of Contents for Vue III

Page 1: ... FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Vue III Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL ...

Page 2: ... 8 SETTING UP A DMX SERIAL DATA LINK 8 STAND ALONE MASTER SLAVE FIXTURE LINKING 9 MOUNTING 9 Orientation 9 Rigging 9 4 OPERATING INSTRUCTIONS 10 OPERATION 10 Stand Alone Mode Sound Active Auto Mode 10 Master Slave Mode Master Sound Master Auto 10 DMX Mode 10 DMX CHANNEL VALUES 11 LED Cluster Values 12 DMX Quick Reference Chart 14 GENERAL TROUBLESHOOTING 15 TECHNICAL SUPPORT 16 5 APPENDIX 16 DMX PR...

Page 3: ...tching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer c...

Page 4: ...e before servicing or replacing lamp or fuse and be sure to replace with same lamp source Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is 95 F 35 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try ...

Page 5: ... in sound activated programs via master slave or DMX Access built in programs in master slave mode via dip switches Additional Features Creates firework like projections Additional power output for daisy chaining units together Low power consumption DMX Channel Summary CHANNEL FUNCTION 1 Operating Mode 2 Cluster 1 3 Cluster 2 4 Cluster 3 5 Cluster 4 6 Cluster 5 7 Cluster 6 8 Cluster 7 9 Strobe Vue...

Page 6: ...erview Tilt Adjustment Knob Hanging Bracket AC Power Input Fuse DMX Input Connector DMX Output Connector Dipswitches Microphone Power Output Connector Sound Sensitivity Knob Vue III User Manual 6 2007 05 10 15 08 ...

Page 7: ... connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures on a serial data link 32 fixtures Data Cabling To link fixtures together you must obtain data cables You...

Page 8: ...d to the shield or each othe RSION CHART Note If you use a controller with a 5 CHAUVET Model No DMX5M The chart below details a proper cable conversion ONVERSION CHART Con tor Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link e of the DMX cable to the output female 3 pin connector tor of the next ...

Page 9: ...quire a slave setting Please consult the Operating Instructions section in this manual for complete instructions for this type of setup and configuration Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING Hanging Clamp It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp...

Page 10: ...daisy chain your units together via the DMX connector on the rear of the units For longer cable runs we suggest a terminator at the last fixture For more information about terminators see page 8 2 Determine which fixture will be the master Connect a DMX cable from the DMX output connector of the master to the DMX input connector of another Vue III 3 Continue connecting the slaves together with DMX...

Page 11: ...ee Static Colors table below 5 000 Ù 031 032 Ù 063 064 Ù 095 096 Ù 127 128 Ù 131 132 Ù 255 Cluster 4 No function Auto mode 1 Auto mode 2 Auto mode 3 No function Static colors see Static Colors table below 6 000 Ù 031 032 Ù 063 064 Ù 095 096 Ù 127 128 Ù 131 132 Ù 255 Cluster 5 No function Auto mode 1 Auto mode 2 Auto mode 3 No function Static colors see Static Colors table below 7 000 Ù 031 032 Ù 0...

Page 12: ...een 1 Red 2 Red 1 Red 2 Red 2 Green 1 Red 1 Green 1 Red 2 Blue 1 Red 1 Blue 1 Green 1 Blue 1 Red 1 Green 1 Blue 1 Red 2 Blue 1 Red 1 Red 2 Blue 1 Green 1 Red 2 Blue 1 Red 1 Green 1 Red 2 Blue 1 Red 3 Red 1 Red 3 Green 1 Red 3 Red 1 Green 1 Red 3 Red 2 Red 3 Red 1 Red 2 Red 3 Green 1 Red 2 Red 3 Red 1 Green 1 Red 2 Red 3 Blue 1 Red 3 Red 1 Blue 1 Red 3 Green 1 Blue 1 Red 3 Red 1 Green 1 Blue 1 Red ...

Page 13: ... the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat st...

Page 14: ... 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 ...

Page 15: ...of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights 9 9 9 9 Moves slow Check 220 110v switch for proper setting 9 No flash...

Page 16: ...ing shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are co...

Page 17: ...d in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within sev...

Reviews: