background image

 

 

 

 

Before You Begin 

Thruster User Manual   

 

2006-10-10

/

13:31

 

Important Safety Information 

This product is designed for professional use. It is not intended for use in a household environment. 

This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet 

radiation, lamp explosion, and injury from falls. 

Read this manual 

before installing or powering the 

fixture, follow the safety precautions listed below and observe all warnings in this manual and on the 

fixture. If you have any questions about how to operate the fixture safely, please contact CHAUVET. 

P r o t e c t i o n   a g a i n s t   E l e c t r i c   S h o c k  

 

Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure 
to replace with same lamp source. 

 

All Class I fixtures must be connected to circuits with a suitable Earth Ground.  

 

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no 
flammable materials close to the unit while operating. 

 

Do not operate the fixture if covers are open or if any internal component is missing or damaged: 
an unshielded discharge lamp emits dangerous UV radiation that can cause burns and eye 
damage. 

 

Make sure power cord is never crimped or damaged.  

 

Never disconnect power cord by pulling or tugging on the cord. 

P r o t e c t i o n   a g a i n s t   F i r e   &   B u r n s  

 

This product is designed to be used with very specific lamp(s). Use of any other type of lamp not 
stated in this manual may create a fire hazard due to possible risk of lamp explosion. Using the 
wrong type of lamp in this product VOIDS the warranty. 

 

Always make sure that you are connecting to the proper voltage and that the line voltage you are 
connecting to is not higher than that stated on decal or rear panel of the fixture. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 
surfaces. Be sure that no ventilation slots are blocked. 

 

Maintain a minimum distance of 1 meter (3.28 feet) from combustible materials. 

 

Allow this product to cool for a minimum of 15 minutes before opening, handling or removing the 
lamp in this product. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate fixture at temperatures higher than 

this.  

P r o t e c t i o n   a g a i n s t   e x p o s u r e   t o   ( U V )   U l t r a vi o l e t   R a d i a t i o n  

 

Avoid direct eye exposure to lamp while it is on.  

 

Do not operate the fixture if covers are open or if any internal component is missing or damaged. 

P r o t e c t i o n   a g a i n s t   I n j u r y   t o   p e r s o n s  

 

Secure fixture to fastening device using a safety chain.  

 

A hot lamp is an explosion hazard. Do not open fixture for a minimum of 15 minutes after 
switching off. Wear eye and hand protection when re-lamping.  

 

Fixture surface may reach temperatures of up to 160° C (320° F). Handle fixture after it cools. 

 

In the event of serious operating problem, stop using the unit immediately. Never try to repair the 
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. 
Please contact the nearest authorized technical assistance center. Always use the same type 
spare parts. 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET.

 

Summary of Contents for Thruster

Page 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 10 10 13 31 Thruster ...

Page 2: ...TTING UP A DMX SERIAL DATA LINK 9 STANDALONE MASTER SLAVE FIXTURE LINKING 9 4 OPERATING INSTRUCTIONS 10 STANDALONE MODE 10 Single Fixture Mode 10 Master Slave Mode 10 Setup Master Fixture 10 Setup Slave Fixtures 11 Sample Master Slave Setup and Linking Visual Guide 11 Table of DIP switch Settings Options Patterns 12 Table of DIP switch Settings for Fixture Values 12 DMX CONTROL MODE 13 Configuring...

Page 3: ...e factory it is important that the fixture be returned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x Thruster Strobe Tube Warranty Card Users Manual Contact Us World Wide General Inform...

Page 4: ... Using the wrong type of lamp in this product VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Maint...

Page 5: ...ith linking output for runway effect Automatic built in programs with sound activation Sound active stand alone mode via DMX Flash speed control Built in programs via DMX Selectable flash patterns with or without DMX controller Runway effect with or without DMX controller Built in automated programs with master slave Built in sound activated programs with master slave Fan cooled DMX Channel Summar...

Page 6: ... Power Switch Speed Rotary knob Audio Sensitivity Rotary knob POWER MIC ON OFF POWER IN DMX IN DMX OUT LINK OUT For thruster only must assign unit a number 1 2 4 8 16 1 2 4 8 16 32 64 128 256 AUDIO SPEED UNIT ASSIGN DMX ADD AS IGN S TM CAUTION Running the Thruster Strobe Tube at full speed for durations exceeding one hour can significantly decrease the life of your lamps Product Overview ...

Page 7: ...ration Mounting Orientation This fixture can be mounted on a truss using a clamp in any position Rigging The fixture includes a mounting yoke to which 1 rigging clamp can be bolted You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture You can order C clamps from any CHAUVET dealer or distributor 1 Block access below the work area and use suitabl...

Page 8: ... If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics ...

Page 9: ...d Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture...

Page 10: ...a link without the use of a controller In a master slave operation the slave fixtures will synchronize and will behave either identically or in a planned chase pattern to the master unit which must be the first in the serial daisy chain A Master Slave Thruster system can consist of up to 31 total fixtures Setup Master Fixture 1 Set DMX ADD ASSIGN DIP switch 10 to the On position and all others to ...

Page 11: ...re DIP switches 1 5 are used to select the running built in pattern for the entire system NOT to address the fixture like in the slave fixtures following In this instance refer to the Table of DIPswitch settings in the page following to choose a programmed pattern The master fixture defaults to Fixture address 1 DIP switches 1 5 are used to set the total number of fixtures in the system DIPswitch ...

Page 12: ...r 0 1 0 1 0 0 0 0 0 1 10 Flow from two ends to center 1 0 1 0 0 0 0 0 0 1 11 All flash 1 1 1 1 0 0 0 0 0 1 Table of DIP switch Settings for Fixture Values Use the following table to quickly set the UNIT ASSIGN DIP switch on the Master unit with the total number of fixtures in your Master Slave setup and to address each Slave fixture accordingly using the DMX ADD ASSIGN DIP switches DIP switch Sett...

Page 13: ...pear consistent and organized Up to 31 Thrusters can be controlled as One Device Configuring Thrusters for Individual DMX control 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a ...

Page 14: ...hannels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference If this is your first time read the DMX Primer in the Appendix Section DMX Input 1 2 3 4 5 6 7 8 9 10 1 2 4 8 16 1 2 4 8 16 32 64 128 256 UNIT ASSIGN DMX ...

Page 15: ...sitive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be p...

Page 16: ...ning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Binary DMX DIP switch Addressing Each DIP switch has an associated value Adding the value of each switch in the ON position will provide the final address Determining which switches to toggle ON given a specific desired address or value can be accomplished ...

Page 17: ...6 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 1...

Page 18: ...255 Program Speed Speed Slow Ù Fast Technical Specifications WEIGHT DIMENSIONS Length 1003 mm 39 5 in Width 76 mm 3 0 in Height 229 mm 9 0 in Weight 5 22 Kgs 11 5 lbs Master Pack 2 pcs 10 66 Kgs 23 5 lbs POWER Operating Voltage 115V 60 Hz AC input IEC 60320 C14 European version 240V 50 Hz Current draw peak 15W 120V FUSE Main 20mm Glass 5A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR ...