Operation
14
Q-Spot™ 460-LED User Manual Rev. 5
Custom Programming
1. Select
RUNMODE > EDIT > STEP
.
2. Select
01~49
, press
<ENTER>
.
a. Select
PAN
, press
<ENTER>
.
i. Set
000~255
to assign the Pan position.
b. Select
TILT
, press
<ENTER>
.
i. Set
000~255
to assign the Tilt position.
c. Select
COLOR
, press
<ENTER>
.
i. Set
000~255
to assign the Color Wheel value.
d. Select
GOBO1
, press
<ENTER>
.
i. Set
000~255
to assign the Gobo 1 Wheel value.
e. Select
GOBO2
, press
<ENTER>
.
i. Set
000~255
to assign the Gobo 2 Wheel value.
f.
Select
GOBO2ROT
, press
<ENTER>
.
i. Set
000~255
to assign the Gobo 2 Rotation value.
g. Select
PRI&ROT
, press
<ENTER>
.
i. Set
000~255
to assign the Prism value.
h. Select
FOCUS
, press
<ENTER>
.
i. Set
000~255
to assign the Focus position.
i.
Select
DIMMER
, press
<ENTER>
.
i. Set
000~255
to assign the Dimmer value.
j.
Select
STROBE
, press
<ENTER>
.
i. Set
000~255
to assign the Strobe value.
k. Select
TIME
, press
<ENTER>
.
i. Set
000~255
to assign the Step duration.
l.
Select
USE
, press
<ENTER>
.
i. Select
YES
to save the settings,
NO
to discard them.
Program Send
1. Select
RUNMODE > SEND
.
2. To send Run mode settings in the Q-Spot™ 460 LED to other Q-Spot™ 460 LED
products connected via Master/Slave, press
<ENTER>
.
a. Select
YES
or
NO
.
b. Press
<ENTER>
.
Manual Settings
Reset Custom Settings
1. Select
MANUAL > RESET
.
2. To reset the custom, press
<ENTER>
.
a. Select
YES
to turn the LCD around or
NO
to keep the normal LCD view.
b. Accept the selected option.