3. S

ETUP

Lamp 

You will need to install a lamp prior to the initial operation of the fixture. A 300W lamp is included. Up 

to a 500W lamp may be used in this fixture. See page 8 for a list of compatible lamps which you can 

order from any Chauvet dealer. 

Warning! 

When replacing the lamp, please wait 15 minutes after powering down to allow the 
unit to cool down! Always disconnect from main power prior to lamp replacement. 

Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp 

with alcohol and wipe it with a lint free cloth before installation. 

Lamp Replacement 

Included Hanging Clamp 

Lamp Access 
Thumbscrew 

1) 

Pull the thumbscrew directly out with one hand until it 
stops.

2) 

With your other hand, pull the back of the fixture away 
from the thumbscrew. 

3) 

Squeeze the retaining spring together and remove it. 

4) 

Remove the lamp socket from the lamp by pulling it 
away from the lamp. 

5) 

Remove the lamp from the fixture. 

6) 

Install a new lamp. 

7) 

Replace the retaining spring. 

8) 

Replace the lamp socket. 

9) 

Replace the top cover. 

Mounting 

O R I E N T A T I O N  

This fixture may be mounted in any position provided there is adequate room for ventilation. 

R I G G I N G    

It is important never to obstruct the fan or vents pathway. Mount the 

fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the 

fixture by loosening both knobs and tilting the fixture. After finding the 

desired position, retighten both knobs. 

x

 

When selecting installation location, take into consideration lamp 
replacement access and routine maintenance.  

x

 

Safety cables should always be used.  

x

 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature 
changes or restricted ventilation. 

PK Par56C User Manual 

6

2006-12-08/12:16

Summary of Contents for PK PAR56C

Page 1: ...FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com PK PAR56C Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL ...

Page 2: ...SAFETY INSTRUCTIONS 4 2 INTRODUCTION 5 FEATURES 5 PRODUCT OVERVIEW 5 3 SETUP 6 LAMP 6 Lamp Replacement 6 MOUNTING 6 Orientation 6 Rigging 6 4 APPENDIX 7 GENERAL MAINTENANCE 7 TROUBLESHOOTING 7 TECHNICAL SUPPORT 7 RETURNS PROCEDURE 8 CLAIMS 8 TECHNICAL SPECIFICATIONS 8 PK Par56C User Manual 2 2006 12 08 12 16 ...

Page 3: ...ing AC Power To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions Before applying power to a fixture check that the source voltage matches the fixture s requirement Warning Verify that the lamp s rated vo...

Page 4: ...connect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source x Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles x Maximum ambient temperature Ta is 95 F 35 C Do not operate fixture at temperatures higher than this x In the event of a serious operating problem stop using t...

Page 5: ...x CH GEL x 1 year limited warranty Note These fixtures can operate at 230V with optional 230V lamps If you wish to run this fixture at 230V you must purchase a compatible 230V lamp from your Chauvet dealer Product Overview Lamp Access Thumbscrew Tilt Adjustment Knob Hanging Bracket Gel Frame Clamp Octagonal Gel Frame PK Par56C User Manual 5 2006 12 08 12 16 ...

Page 6: ...he thumbscrew 3 Squeeze the retaining spring together and remove it 4 Remove the lamp socket from the lamp by pulling it away from the lamp 5 Remove the lamp from the fixture 6 Install a new lamp 7 Replace the retaining spring 8 Replace the lamp socket 9 Replace the top cover Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It...

Page 7: ...y to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Trou...

Page 8: ...1 Your name 2 Your address 3 Your phone number 4 The RA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim f...