Chauvet OVATION FD-205WW User Manual Download Page 14

Page 12 of 22

 O

PERATION

Ovation FD-205WW User Manual Rev. 1

Menu Map

Main Level

Programming Levels

Description

STATIC

DIMMER

0-100

Local control of output

ZOOM

Local control of zoom lens

RUN MODE

DMX 512

Sets the mode to DMX control

SLAVE 

Sets the mode to master/slave

DMMR

Sets the mode to dimmer control, 

which turns off data input

SENS

Automatically chooses between 

DMMR

 and 

DMX

POWER 

MODE

575W

Matches output to 575W 

incandescent fixture

750W

Matches output to 750W 

incandescent fixture

ADDRESS

001-512

Sets the starting address

MOTOR

YES

Resets the Zoom Motor

NO

SETTING

KEY

ON

Sets the key lock (Passcode 

mode)

OFF

DIMMER

OFF 

No dimmer

DIM1

Slow (

DIM4

) to fast (

DIM1

dimmer speeds

DIM2
DIM3
DIM4

CURVE

OFF

No dimmer

CURVE1

Large (

CURVE3

) to small 

(

CURVE1

) dimmer curves

CURVE2
CURVE3

PERSONALITY

UNO

Selects DMX personality

DOS

STD.P

SLOCK

ON

SETTING

 menu level access lock

OFF

DMX ERROR

SAVE

Continues with last command 

upon loss of DMX control

BLACK

Blacks out fixture upon loss of 

DMX

RESET

PASS CODE

(Enter Passcode)

Resets fixture to factory defaults

ZOOM

BASE

Sets default zoom position 

(full movement)

POSE1

Sets position 1 setting for zoom 

limit

POSE2

Sets position 2 setting for zoom 

limit

PERFORM

LIVE

Balances LED cooling using fans 

and output power level

STUDIO

Maintains LED cooling by limiting 

output power level

MODE SETTING

SELF 

No DMX data is sent in 

standalone operation

MAST

Sends DMX data to other Ovation 

FD-205WW during standalone 

operation

Summary of Contents for OVATION FD-205WW

Page 1: ...User Manual...

Page 2: ...consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the printer to scale the con...

Page 3: ...8 AC Plug 8 Power Linking 8 Fuse Replacement 8 DMX Linking 8 DMX Personalities 8 Remote Device Management RDM 9 Master Slave Connectivity 9 Dimmer Modes 9 Mounting 9 Orientation 9 Rigging 10 Procedur...

Page 4: ...ges 16 Resetting the Zoom Motor 16 Zoom Menu Control 16 Zoom Manual Control 16 LED Frequency 16 Power Performance Output Options 17 Power Output Options 17 System Information 17 5 Technical Informatio...

Page 5: ...205WW Neutrik powerCON power cord Gel frame 7 5 in 191 mm accessories Quick Reference Guide Convention Meaning 1 512 A range of values 50 60 A set of values of which only one can be chosen SET A butt...

Page 6: ...device using a safety cable Power and Wiring Always make sure you are connecting the product to the proper voltage in accordance with the specifications in this manual or on the product s specificatio...

Page 7: ...dimming systems Features 1 2 or 5 channel Warm White LED wash product Operating modes 1 channel Dimmer UNO 2 channel 16 bit Dimmer DOS 5 channel 16 bit Dimmer strobe zoom motor reset Works perfectly...

Page 8: ...er Manual Rev 1 Product Overview 3 Pin DMX In Gel Frame Holder Clip 3 Pin DMX Out 5 Pin DMX In 5 Pin DMX Out Power Out Fuse Voltage Input Switch Zoom Control Knob Dimmer Control Knob Menu Buttons Powe...

Page 9: ...Page 7 of 22 Ovation FD 205WW User Manual Rev 1 INTRODUCTION Product Dimensions 7 80 in 198 mm 11 18 in 284 mm 14 92 in 379 mm 9 37 in 238 mm 6 65 in 169 mm 8 82 in 224 mm...

Page 10: ...he housing 3 Remove the blown fuse and replace with another fuse of the same type and rating T 3 15 A 250 V 4 Screw the fuse holder cap back in place and reconnect power DMX Linking You can link the O...

Page 11: ...en in SENS mode advanced onboard electronics automatically detect what type of power and data the product receives and it responds accordingly This is the factory default setting When in DMX mode the...

Page 12: ...ount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multip...

Page 13: ...tings 1 Go to the SETTING main level 2 Select KEY 3 Choose ON or OFF Settings Lock This setting enables you to activate or disable the settings lock which keeps non authorized personnel from making an...

Page 14: ...No dimmer DIM1 Slow DIM4 to fast DIM1 dimmer speeds DIM2 DIM3 DIM4 CURVE OFF No dimmer CURVE1 Large CURVE3 to small CURVE1 dimmer curves CURVE2 CURVE3 PERSONALITY UNO Selects DMX personality DOS STD...

Page 15: ...option see Master Slave Mode 3 Set the starting address a Go to ADDRESS main level b Select the starting address 001 512 The highest recommended starting address for each DMX mode is as follows SETTI...

Page 16: ...ia the dimmer 1 Go to the RUN MODE main level 2 Choose DMMR or SENS Dimmer Menu Control To adjust the light output of the Ovation FD 205WW select the dimmer setting as follows 1 Go to the STATIC main...

Page 17: ...ster mode MAST while the slaves will be set to operate in Slave mode SLAVE Once set and connected the slaves will operate in unison with the master To set each of the slaves 1 Go to the RUN MODE main...

Page 18: ...r POSE2 position 2 5 Select the desired maximum for the zoom 000 255 0 100 6 Repeat to select the other position setting Resetting the Zoom Motor To reset the zoom motor do the following 1 Go to the M...

Page 19: ...utput level Select STUDIO to cool the LEDs by maintaining the use of the fan and limiting the power output level Power Output Options The Ovation FD 205WW offers two output modes to reasonably duplica...

Page 20: ...increased mechanical wear To clean the product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust coll...

Page 21: ...A Power linking current products 13 6 A 8 products 13 6 A 16 products Fuse T 3 15 A 250 V T 3 15 A 250 V Power I O U S Canada Worldwide Power input connector Neutrik powerCON Neutrik powerCON Power o...

Page 22: ...VSDF m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m FBN JFME FBN JFME Distance Beam Diameter Field Diameter Wide Narrow Beam Field Field Footcandle Diameter Diameter Footcandl...

Page 23: ...RMA number Chauvet will refuse any product returned without an RMA number Once you have the RMA number provide the following information on a piece of paper and place it inside the box Your name Your...

Page 24: ...eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Chauvet Europe BVBA Address Stokstraat 18 Email BNLtec...

Reviews: