EN
Nexus™ Aq 5x5 QRG
3
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
Power Linking
You can link up to 5 Nexus™ Aq 5x5 products at 120 V, 8 products
at 208 V, or 9 products at 230 V. Never exceed this number. Power linking
cords can be purchased separately.
Power Linking
Diagram
AC Plug
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Replacing the
Fuse
1.
Disconnect this product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the
housing.
3.
Remove blown fuse and replace with a good fuse of the same type and
rating.
4.
Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Nexus™ Aq 5x5 will work with a DMX controller using a regular
DMX serial connection. A DMX Primer is available from
www.chauvetpro.com
.
DMX Connection
The Nexus™ Aq 5x5 uses a regular DMX data for its DMX personalities:
4
,
6
,
10
,
100
, and
105
. See the User Manual to connect and configure for
DMX operation.
Master/Slave
Connection
The Nexus™ Aq 5x5 uses the DMX data connection for its Master/Slave
mode. See the User Manual to connect and configure for Master/Slave
operation.