Menu Map
MinSpot 11
2007-08-23/15:49
Page 1: ...Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle MiNSpot USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954...
Page 2: ...FIGURATIONS 12 To set the pan to inverting or non inverting 12 To set the tilt to inverting or non inverting 12 To set the LED Readout to Inverting or Non Inverting 12 To set the DMX channel configura...
Page 3: ...verage current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or di...
Page 4: ...ource before servicing or replacing fuse and be sure to replace with same fuse size and type Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its...
Page 5: ...AL FEATURES User selectable basic or advanced operating modes User selectable pan tilt ranges Pan 540 360 180 Tilt 270 180 90 Compact and lightweight LED display menu with invert Reset to factory sett...
Page 6: ...1 Pan 2 Tilt 3 Shutter 4 Color Macro 5 Gobo Product Overview Projector Head Lens Focus LED Readout Control Panel DMX In DMX Out IEC Power Connector with Fuse holder Rear Voltage Selector Switch rear C...
Page 7: ...data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended seria...
Page 8: ...not allow contact between the common and the fixture s chassis ground Grounding the common verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each othe RSI...
Page 9: ...a male 3 pin connector Then ounting RIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It is important never to obstruct the fan or vents pa...
Page 10: ...ER DOWN UP MODE ESC The Control Panel LED Display shows the menu items you select from the menu map on page 11 When a menu function is selected the display will show immediately the first available op...
Page 11: ...Menu Map MinSpot 11 2007 08 23 15 49...
Page 12: ...CHANNEL CONFIGURATION 1 Press the Mode button until it shows or 2 Use the Up Down buttons to set to the desired inversion press enter to confirm TO SET THE MAXIMUM PAN ANGLE 1 Press the Mode button un...
Page 13: ...ture For more information about terminators see page 8 2 Choose a unit to function as the Master Select NAFA NASL or NStS see below for readout depending upon which master mode you require The master...
Page 14: ...reen Light Blue Teal Sky Blue Blue Olive Turquoise Orange Yellow Magenta White Color Change Macro 1 Color Change Macro 2 Color Change Macro 3 Color Change Macro 4 11 000 255 Vector Speed Color 12 000...
Page 15: ...127 128 139 140 151 152 163 164 175 176 187 188 199 200 212 213 225 226 239 240 255 Color Macros No Function Magenta Purple Orange Pink Yellow Pale Green Light Blue Teal Sky Blue Blue Olive Turquoise...
Page 16: ...rmine the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest va...
Page 17: ...7 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0...
Page 18: ...of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before po...
Page 19: ...of the fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison m...
Page 20: ...y Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags...
Page 21: ...GHT SOURCE LED 1 14W RGB 50 000hrs PHOTO OPTIC Beam Angle 13 Illuminance at 1M 100 fc 1 076 lux RANGE Pan 540 Tilt 270 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input loc...