Operation
-12-
Legend™ 412 Series User Manual Rev. 04
DMX Control
In this mode, each product will respond to a unique starting address from the DMX
controller. All products with the same starting address will respond in unison.
1. Select a DMX personality as shown in the
DMX Personality
section.
2. Set the starting address:
a. Go to
Addr
and press
<ENTER>
.
b. Select the starting address (
001~512
).
The highest recommended starting address for each DMX mode are as follows:
Legend™ 412
Legend™ 412 VW
DMX Mode DMX Address DMX Mode DMX Address
Advanced
485
Advanced
493
Basic
501
Basic
503
Static Color
The Static mode allows for permanent positioning, strobing, dimming, and RGBW or VW
color mixing without a DMX controller.
1. Go to
NAnu
and press
<ENTER>
.
2. Select the desired position (
Pan
or
tILt
).
3. Select the desired position value (
0
~
255
).
4. Repeat for the other position.
5. Select the desired color based on the product.
Legend™ 412:
Red1~4
,
Gre1~4
,
bLu1~4
, or
UhI1~4
.
Legend™ 412 VW:
UU1~4
, or
CU1~4
.
6. Select the desired color value (
0
~
255
).
7. Repeat for the other colors.
8. Select the desired intensity (
dINN
).
9. Select the desired intensity value (
0
~
255
).
10. Select Strobe effect (
Stro
).
11. Select the desired frequency (
0
~
255
).
Auto Programs
Auto programs allow for dynamic RGBW (Legend™ 412) or VW (Legend™ 412 VW) color
mixing without a DMX controller.
1. Go to
Shnd
and press
<ENTER>
.
2. Select the desired auto program (
Sh 1~4
).
You cannot edit any of the auto programs (Sh 1~4).