4. Operating Instructions
9
4/19/2010 1:08 PM
Master/Slave Mode (Sound-Active, Auto Mode, Static Colors)
This mode allows a single unit to run a standalone program, while 1 or more other units follow the
same operation. This requires the fixtures to be linked with DMX cables. Please see the section on
Fixture Linking
.
1)
The Master unit may be operated in
Automatic, Sound-Active
, and
Static Colors
.
2)
Adjust the DIP switches to the Slave position on the slave units, and they will react the same as
the Master. See below for DIP switch assignment.
Mode
DIP switches
Slave
2~11 = Off
1 = On
Strobe Speed
This fixture has a strobe speed adjustment which will decrease the maximum speed. Please see the
setting below for lowering the strobe rate for compatibility mode.
Mode
DIP switches
Standard mode
6 Hz~18 Hz:
12 = On
Decreased Speed
2 Hz~6 Hz:
12 = Off