4. Operating Instructions 

The TFX-UVLED is a DMX-512 controllable, flash UV LED panel made up of highly efficient and 

super bright UV LEDs. The TFX-UVLED can operate in Stand-Alone, Master/Slave and via DMX-512 

control utilizing 3 channels.  

Standalone Mode 

The TFX-UVLED can be operated without a DMX controller 

in a standalone mode. It can be operated as a single fixture 

or together with several other TFX-UVLED fixtures in what is 

called a “Master/Slave” configuration. 

Single-Fixture Mode 

The TFX-UVLED can be set to operate independently of other fixtures or a DMX controller in either a 

sound-active or automatic mode. A serial data-link is not necessary for this mode of operation and it 

is recommended that no connection to other fixtures be made at all.  

1.  Simply choose from any one of 10 built-in “DIP-switch Options” from the table below.  

Master-Slave Mode 

A master-slave mode setup consists of more than one fixture connected in a serial data link without 

the use of a controller. In a master-slave operation the slave fixtures will synchronize and will behave 

either identically or in a planned chase pattern to the master unit which must be the first in the serial 

daisy chain. A Master-Slave TFX-UVLED system can consist of an unlimited range of fixtures or at 

least the number stated to conform to EIA-485 standards. 

S e t u p  

1.  The TFX-UVLED sets up automatically for Master-Slave, no DIP-switch settings are required other 

than for selecting DIP-switch Options. 

2. 

Connect the end of the cable coming from the first fixture which will have a (female) 3 pin 
connector to the 

DMX IN 

input connector of the Slave fixture consisting of a (male) 3 pin 

connector. Continue the loop from 

DMX OUT

 to 

DMX IN. 

Dipswitch Options 

Functions 

Dipswitches ( ON ) 

Notes & Description 

Sound Active 

None 

Music: Sound Activated, Rotary knob sets sound sensitivity 

Flash Speed 1 

Flash Speed 2 

Flash Speed 3 

Flash Speed 4 

Flash Speed 5 

Flash Speed 6 

Flash Speed 7 

Flash 

Flash Speed 8 

Full On 

All LEDs full on 

Preset Program 

10 

Preset Programs run in Automatic speed 

 

Summary of Contents for LED Shadow TFX-UVLED

Page 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 10 11 12 19 LED Shadow TFX UVLED USER MANUAL ...

Page 2: ... AC POWER 7 MOUNTING 7 FIXTURE LINKING 8 Data Cabling 8 DMX Data Cable 8 Cable Connectors 8 3 Pin to 5 Pin Conversion Chart 9 SETTING UP A DMX SERIAL DATA LINK 9 STANDALONE MASTER SLAVE FIXTURE LINKING 9 4 OPERATING INSTRUCTIONS 10 STANDALONE MODE 10 Single Fixture Mode 10 Master Slave Mode 10 Setup 10 Dipswitch Options 10 DMX CONTROL MODE 11 Configuring for DMX control 11 Setting the DMX address ...

Page 3: ...that the fixture be returned in the original factory box and packing Note If you should require sending any items back to CHAUVET call CHAUVET for a RMA Return Merchandise Authorization number The factory will not allow any shipments without an RMA Your shipment includes the following 1 x LED Shadow TFX UVLED 1 x Power cable 2 x Flush Mount Brackets with screws Warranty Card Users Manual Contact U...

Page 4: ... Using the wrong type of lamp in this product VOIDS the warranty Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Maint...

Page 5: ...s manual Control mode parameters are set by DMX values in Channel 1 2 Introduction Features 3 channel DMX 512 LED UV blacklight Blackout static dimmer strobe Built in automatic programs Adjustable flash rate dimmer and static via stand alone Automatic built in programs with sound activation Linkable with LED Techno Strobe LED Techno Strobe RGB in stand alone Coverage up to 15ft x 30ft Low power co...

Page 6: ...9 DMX Input DIP switches DMX Addressing IEC Plug for AC Input Fuse Compartment DMX Output LED Front Panel Hanging Yoke Audio Sensitivity Rotary knob Red LED Power Indicator Blue LED Signal Indicator Power Link Out Flush Mounting Bracket Product Overview ...

Page 7: ... fixture can be mounted on a truss using a clamp in any position or against a flat surface using the brackets provided Rigging The fixture includes a mounting yoke to which 1 rigging clamp can be bolted and 2 Flush Mount Brackets for flush mounting to flat surfaces You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture You can order C clamps from...

Page 8: ...e If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics...

Page 9: ...round Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fix...

Page 10: ...ave mode setup consists of more than one fixture connected in a serial data link without the use of a controller In a master slave operation the slave fixtures will synchronize and will behave either identically or in a planned chase pattern to the master unit which must be the first in the serial daisy chain A Master Slave TFX UVLED system can consist of an unlimited range of fixtures or at least...

Page 11: ...etting the DMX address read the section titled Setting the DMX address in this Chapter Setting the DMX address Each fixture requires a start address from 1 to 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would ...

Page 12: ...ositive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be ...

Page 13: ...g fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Binary DMX DIP switch Addressing Each DIP switch has an associated value Adding the value of each switch in the ON position will provide the final address Determining which switches to toggle ON given a specific desired address or value can be accomplished in ...

Page 14: ...6 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 1...

Page 15: ...e while Channel 1 is set between 000 and 029 the following conditions will apply Channel 2 will control Dimming Intensity from 0 to 100 Channel 3 will control Dimming Intensity from 100 to 0 Channel Value Function Ch 2 Ch 3 000 Ù 029 Dimmer Mode Flash Speed 0 Ù 100 030 Ù 059 Program 1 060 Ù 089 Program 2 090 Ù 119 Program 3 120 Ù 149 Program 4 150 Ù 179 Program 5 180 Ù 209 Program 6 Speed Slow Ù F...

Page 16: ...h 24W 120V FUSE Main 20mm Glass 2A Fast Blow LED Quantity 192 Total UV CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 3 ORDERING INFORMATION LED Shadow TFX UVLED Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email te...