background image

 

 

LED PAR 56-24UVB 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

User Manual 

Summary of Contents for LED PAR 56-24UVB

Page 1: ...LED PAR 56 24UVB User Manual ...

Page 2: ... POWER 6 Power Linking 6 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 CONFIGURING THE STARTING ADDRESS 8 CONTROL PANEL FUNCTIONS 8 Menu Map 8 DMX Operation 9 Master Slave Mode Sound Active Auto Mode 9 Automatic 10 Sound Active 10 Static Dimmer 10 DMX CHANNEL VALUES 10 5 APPENDIX 11 GENERAL TROUBLESHOOTING 11 DMX PRIMER 12 FIXTURE LINKING DAISY CHAIN 12 DATA CABLING 12 DMX Data Cab...

Page 3: ... regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This ...

Page 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Page 5: ...ower Input Microphone Microphone Sensitivity Adjustment Knob Fuseholder Bracket Adjustment Knob Attachment Bolt not meant to be adjusted DMX Out Power Output Control Panel LED display Power Output Gel Frame Gel Frame Release Bracket Adjustment Knob Hanging mounting 13 mm hole ...

Page 6: ...rcuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of LED PAR 56 24UVB that may be linked is 18 The power link...

Page 7: ... gel frame release so that it is pointing up Please see the diagram below for a visual reference If you intend to use the power link out with multiple fixtures consider the length of each power cable and mount the fixtures close enough to one another to account for this When aiming the fixtures you may use the bracket adjustment knob Loosen the knob adjust to the desired angle and then tighten the...

Page 8: ...e BUTTON FUNCTION MENU Used to scroll through the current operating mode as well as back out of the current menu option UP Used to select increasing advancement in the value DOWN Used to select decreasing advancement in the value ENTER Used to select a value and store it to memory Menu Map MAIN FUNCTION SUB FUNCTION SELECTION SUB SELECTION DESCRIPTION 512 d001 d512 DMX Mode Select for DMX mode and...

Page 9: ...mode allows a single unit to run to the beat of the music or the unit will change automatically DMX cables must be used to daisy chain between the fixtures from the output of the master unit Master 1 Set the master unit to run in either Automatic mode or Sound Active mode Please see the appropriate sections on this user manual for instructions on this process Slave 1 Press MENU until 512 appears o...

Page 10: ...ntrol panel on the front of the fixture and the speed may be adjusted using the audio adjustment knob Please see the chart below for further explanation 1 Press MENU until SNd appears on the LED screen 2 Press ENTER 3 Use the microphone sensitivity adjustment knob to adjust the microphone sensitivity Static Dimmer This fixture has a variable static dimmer mode Access this via the control panel on ...

Page 11: ...ng Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier r...

Page 12: ... pin 2 is Data Negative S and pin 3 is Data positive S Fixture Linking Daisy Chain You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a daisy chain determines the number of fixtures the data link can sup...

Page 13: ...o read the data on the channel indicated by the start address For example a fixture that uses six DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference If this is your first time addressing a fixture using the DMX co...

Page 14: ...n 4 Not used Pin 5 Setting up a DMX Daisy Chain 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Then proceed to connect from the output as stated above to ...

Page 15: ... days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUVE...

Page 16: ... Consumption 120 V 35 W 0 5 A max 0 5 A inrush Power Consumption 230 V 31 W 0 5 A max 0 5 A inrush Power output 18 units max LIGHT SOURCE LED 24 1 W UV 50 000 hrs PHOTO OPTIC Coverage angle 23 INDOOR OUTDOOR Rating For indoor use only THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LED PAR 56 24UVB LEDPAR5624UVB WARRANTY INFORMATION Warranty 2 year limited warranty ...

Page 17: ...0 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com ...

Reviews: