background image

World-wide Headquarters:

3000 North 29th Ct., Hollywood, Florida, USA, FL 33020

Tel: +1-954-929-1115   Fax: +1-954-929-5560

www.ChauvetLighting.com

LAZER SCAN

LGG-3100X

User Guide

Please read these instructions carefully before use

Summary of Contents for LAZER SCAN LGG-3100X

Page 1: ...e Headquarters 3000 North 29th Ct Hollywood Florida USA FL 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 www ChauvetLighting com LAZER SCAN LGG 3100X User Guide Please read these instructions carefully before use ...

Page 2: ... in well ventilated areas taking care not to obstruct the air vents After use allow time to cool for safety and to ensure longevity before moving or touching The Lazer Scan LGG3100X is a DMX fixture that can be operated with Chauvet s DMX 6 controller DMX 40 DMX controller ShowXpress or any other universal DMX controller The LGG3100X will also work in stand alone mode either automatic or sound act...

Page 3: ...l 2 and 3 are set at 255 the LGG3100X will function in stand alone beat activation mode 1 Set SW 10 to OFF 2 Count the value of the switches in the on position and SW 4 equals 8 3 Set SW 3 and SW 4 to the ON position 4 8 12 1 2 3 4 5 6 7 8 9 10 Off On Value 1 2 4 8 16 32 64 128 256 ...

Page 4: ...tion at all when connected to the main power supply i e the mechanism does not spin Then it is highly likely that the fuse has blown Disconnect from main power supply before attempting to replace either lamps or fuse In order to replace the fuse disconnect from the main power supply first and then unscrew the fuseholder cover to reveal the fuse The unit has a label attached which indicates the cor...

Page 5: ...you still have a problem contact your dealer or CHAUVET Contact Chauvet USA Tecnical Assistance 1 800 762 1084 954 929 1115 E Mail tech chauvetlighting com Caution Do not obstruct the air vents Do not touch unit while hot No user serviceable parts inside please refer to CHAUVET for service Unit should be mounted in such a manner that the emitted beam will no strike people Power Connections The uni...

Page 6: ...N o t i c eN o 5 0 d a t e dJ u l y2 6 2 0 0 1 Caution use of controls or adjustments or performance of procedures other than as specified herein may result in hazardous radiation exposure Warning Do not look directly into the Laser Prolonged exposure to single static laser beam can cause retinal damage CAUTION CLASS 3R L A S E R R A D I A T I O N W H E N OPEN AVOID DIRECT EYE EXPOSURE CAUTION CLA...

Reviews: