 The fuse is located 
inside this 
compartment. 
Remove using a flat 
head screwdriver. 

 

4.

 

S

ETUP

 

Fuse Replacement 

With a flat head screwdriver wedge the fuse 

holder out of its housing. Remove the damaged 

fuse from its holder and replace with exact 

same type fuse. Insert the fuse holder back in 

its place and reconnect power.  

 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller 

or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The 

combined number of channels required by all the fixtures on a serial data link determines the number 

of fixtures the data link can support.  

Important:  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the 

EIA-485 standard no more than 32 fixtures should be connected on one data link. 

Connecting more than 32 fixtures on one serial data link without the use of a DMX 

optically-isolated splitter may result in deterioration of the digital DMX signal.  

Maximum recommended serial data link distance: 500 m (1640 ft)  

Maximum recommended number of fixtures on a serial data link: 32 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX 

cables directly from a dealer/distributor or construct your own cable. If you choose to create your own 

cable please use data-grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference. 

DMX Data Cable 

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. 

Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must 

have the following characteristics: 

2-conductor twisted pair plus a shield 
Maximum capacitance between conductors 

– 30 pF/ft. 

Maximum capacitance between conductor and shield 

– 55 pF/ft. 

Maximum resistance of 20 ohms / 1000 ft. 
Nominal impedance 100 

– 140 ohms 

 

 

Disconnect the power cord before replacing a fuse and always 
replace with the same type fuse. 

 

 

Summary of Contents for Kinta X

Page 1: ...0 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Kinta X User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave Autoswitching Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Page 2: ... Pin to 5 Pin Conversion Chart 7 SETTING UP A DMX SERIAL DATA LINK 7 MOUNTING 8 Orientation 8 Rigging 8 5 OPERATING INSTRUCTIONS 9 OPERATION 9 Stand Alone Mode Sound Active Auto Mode 9 DMX Mode 9 DMX CHANNEL VALUES 9 Setting the Starting Address 10 DMX Quick Reference Chart 11 6 APPENDIX 12 DMX PRIMER 12 GENERAL MAINTENANCE 13 RETURNS PROCEDURE 13 CLAIMS 13 GENERAL TROUBLESHOOTING 14 CONTACT US 15...

Page 3: ...ecal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disco...

Page 4: ...ted programs via standalone or DMX Built in sound activated programs via standalone Additional Features High power 3 W 730 mA LEDs Linkable with LED Mushroom and Double Derby X Mount multiple units together with adjustable optional bracket XBRACKET Additional power output max 37 units DMX Channel Summary CHANNEL FUNCTION 1 Control Operating Mode 2 Motor rotation ...

Page 5: ...Kinta X User Manual 5 7 23 2009 5 23 PM Product Overview Sound sensitivity adjustment Dipswitches DMX Out DMX In Power link out Power In Hanging mounting bracket Bracket adjustment knob ...

Page 6: ...serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 m 1640 ft Maximum recommended number of fixtures on a serial data link 32 Data Cabling To link fixtures together you must obtain data cables You can purchase CHAUVET certified DMX cables directly from a dealer distributor or c...

Page 7: ... 5 PIN CONVERSION CHART Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not Used Pin 4 Not Used Pin 5 Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a fem...

Page 8: ...e of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables must always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Do n...

Page 9: ...he knob counterclockwise decreases the sensitivity turning the knob clockwise increases the sensitivity DMX Mode This mode allows the unit to be controlled by any universal DMX controller If you are unfamiliar with DMX please read the DMX Primer 1 Set DIP switches position to DMX mode Mode DIP switches DMX 10 On 2 Use DIP switches 1 9 to set the DMX address DMX Channel Values CHANNEL VALUE FUNCTIO...

Page 10: ...y doing the following 1 Determine the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the...

Page 11: ...64 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146...

Page 12: ...control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next ...

Page 13: ...uid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET an...

Page 14: ...fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Moves slow Check 220 110v switch...

Page 15: ...7 mm Height 10 4 in 264 mm Weight 6 lbs 2 7 kg POWER Autoswitching 100 240 VAC 50 60 Hz Fuse 2 A 250 V Power Consumption 24 W 0 2 A max 120 V Inrush Current 0 5 A 120 V Power Output 37 units max LIGHT SOURCE LED 3 x 3 W 730 mA 1 Red 1 Green 1 Blue 50 000 hrs PHOTO OPTIC Coverage Angle 135 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Da...

Reviews: