background image

 

 

 

Intimidator

™ Scan LED 

10 

2009-06-04/10:14 

Setting the Starting Address 

If this is your first time addressing a fixture using the DMX-512 control protocol, 
you should skip 

to the Appendix and read the “DMX Primer” section. It contains 

very useful information that will help you understand how it works.   

Set the starting address using the group of DIP switches located usually on bottom of the fixture. 

Each DIP switch has an associated value. Adding the value of each switch in the ON position will 

provide the starting address. The following instructions will help you to figure out which switches to 

toggle ON given a specific starting address: 

1) 

Determine the largest value switch that is less than the starting address. Turn this switch on. 

2) 

Subtract the value of the switch you just turned on from the starting address number. 

3) 

Determine the largest value switch that is less than the remainder from the previous subtraction. 

Turn this switch on. 

4) 

Subtract the value of the switch you just turned on from the remainder of the previous 

subtraction. 

5) 

Repeat steps three and four until you have a remainder of zero. 

E

XAMPLE 

S

TARTING 

A

DDRESS

 

 

Address 10 

Switch # 4 

= 8 

Switch # 2 

= 2 

Total  

= 10 

 

Address 26 

Switch # 5  = 16 

Switch # 4  = 8 

Switch # 2  = 2 

Total 

= 26 

 

Resolving the starting 
address using simple math. 

Address 233 

 
233 

– (128) = 105 - Turn ON Dip # 8 

 
105 

– (64) = 41 - Turn ON Dip # 7 

 
41 

– (32) = 9 - Turn ON Dip # 6 

 

– (8) = 1 - Turn ON Dip # 4 

 

– (1) = 0 - Turn ON Dip # 1 

D

IPSWITCH

  (DMX

 

V

ALUE













16 
32 
64 
128 
256 

 

 

1

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

2

2

2

2

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

1

2

3

4

5

6

7

8

9

ON
OFF

1

2

4

8

16

32

64

128

256

Summary of Contents for Intimidator SCAN LED

Page 1: ...020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX 512 Master Slave Autoswitching Power Supply Replaceable Fuse User Serviceable Duty Cycle ...

Page 2: ...KING 5 DMX Data Cable 5 Cable Connectors 5 3 Pin to 5 Pin Conversion Chart 6 Setting up a DMX Serial Data Link 6 Master Slave Fixture Linking 6 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand alone 8 Master Slave 8 DMX Mode 8 USING DMX MODE 8 DMX Channel Values 9 Setting the Starting Address 10 DMX Quick Reference Chart 11 CA 9 EASY CONTROLLER OPTIONAL 12 GENE...

Page 3: ...rmation Failure to comply with this information may prevent the system from functioning correctly This paragraph reminds you of useful although not critical information AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages 100 V 240 VAC 50 60 Hz Before powering on the unit make sure the line voltage to which you are connecting it is within the...

Page 4: ...e contact the nearest authorized technical assistance center Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on Do not daisy chain power to more than 20 units 120 V There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs In the un...

Page 5: ...view Mirror Hanging Yoke double bracketed for floor positions Double bracketed yoke used for floor positions Power Fuse compartment Microphone Sound Sensitivity Knob Remote Controller Input DMX connectors Manual focus adjustment Power out Safety eyebolt ...

Page 6: ...he instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with any gobo of your choice pointed to a flat surface ideally at a halfway point of the fixture s total coverage area 3 Rotate the manual focus either clockwise or counter clockwise until the spot is defined by a hard edge Fuse Re...

Page 7: ...m a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable must ...

Page 8: ... the output female 3 pin connector of the controller 2 Connect the other end of the cable to the male 3 pin input connector of the first fixture 3 Connect the cable from the output of the first fixture to the input of the second fixture 4 Continue connecting the other features as indicated above CHAUVET Certified DMX Data Cables Order Code Description DMX1 5 DMX Cable 1 5 m 4 9 ft DMX4 5 DMX Cable...

Page 9: ...e C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting an installation location consider ease of access for routine maintenance Always use safety cables Never mount the unit in places where it will be exposed to rain high humidity extreme temperature changes or restricted ventilation...

Page 10: ...in a daisy chain fashion In this mode the first unit in the daisy chain will automatically command all other units following regardless of their DIP switch settings See the Setup section for instructions on how to connect the various units DMX Mode This mode allows the unit to be controlled by any universal DMX controller Using DMX Mode If you are unfamiliar with DMX please read the DMX Primer sec...

Page 11: ... 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 255 Gobo Blackout Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo Spin Slow Fast 3 000 010 011 012 022 023 033 034 044 045 055 065 066 076 077 087 088 098 099 109 110 120 121 127 128 255 Color Open White Red Cyan Yellow Green Magenta Light Blue Dark Yell...

Page 12: ...witch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat steps three and four until you have a remainder of zero EXAMPLE STARTING ADDRESS Address 10 Switch 4 8 Switch 2 2 Total 10 Address 26 Switch 5 16 Switch 4 8 Switch 2 2 Total 26 Resolving the starting address using simple math Address 233 233 128 105 Turn ON Dip 8 105 64 41 Turn ON...

Page 13: ...08 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 46...

Page 14: ...p through the 11 colors then once more to step to the next gobo LED OFF Fast Mode The unit s movement Pan Tilt and Gobo Color is sound activated Press and hold the Function button to achieve the following results a Strobe in different colors and gobos b Synchronous strobe in white c Two light strobe in white color CA 9 Easy Controller Daisy Chain Connection To other units Remote Control Jack CA 9 ...

Page 15: ...n the control switches If audio provided via jack make sure a live audio signal exists Adjust sound sensitivity knob Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again Wait 5 to 10 minutes before powering it up again Loss of signal Use only DMX cables Install terminator Note Keep DMX cables sepa...

Page 16: ...04 and 105 The user must assign a starting address on the fixture that indicates the first channel reserved in the controller There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required Choosing a start address should be planned in advance Channels should never overlap If they do this will result in erratic operation of the fixtures wh...

Page 17: ...aning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CH...

Page 18: ...max 230 V Inrush Current 0 3 A 230 V Power Output 20 units max 120 VAC 40 units max 230 V LIGHT SOURCE LED 22 W 1 360 mA 1 White 50 000 hrs PHOTO OPTIC Luminance 1m 1 530 lux Beam angle 15 THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols D...