Disconnect the product from the power outlet before replacing the fuse.
Fuse
Replacement
1. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2. Pry the fuse holder out of the housing.
3. Remove the blown fuse from the holder and replace with a fuse of the exact same
type and rating.
4. Insert the fuse holder back in place and reconnect power.
The product does not ship with a spare fuse; however, the safety cap has room
for a spare.
Always replace a blown fuse with a fuse of the same type and rating.
Power Linking
The product provides power linking via the IEC outlet located in the back of the unit.
Please see the diagram below for further explanation.
Power Linking
Diagram
You can power link up to twelve (12) Freedom™ Par units on 120 VAC or up to
twenty-two (22) Freedom™ series units on 230 VAC.
You can power link up to seventeen (17) Freedom™ Strip Mini units on 120 VAC or
up to thirty-two (32) Freedom™ series units on 230 VAC.
The power linking diagram shown above corresponds to the North American
version of the product ONLY! If using the product in other markets, you must
consult with the local CHAUVET® distributor because power linking connectors
and requirements may differ in your country or region.
•
1
st
Product
2
nd
Product
3
rd
Product
Other products
Installed fuse
(held by plastic clip)
Spare fuse holder
(inside safety cap)
Safety cap
Summary of Contents for Freedom Par
Page 1: ...User Manual ...
Page 9: ...Freedom series User Manual Rev 6 ML Page 9 of 76 Product Dimensions Freedom Par ...
Page 10: ...Page 10 of 76 Freedom series User Manual Rev 6 ML Product Dimensions Freedom Strip Mini ...
Page 31: ...Manual de Usuario serie Freedom Rev 6 ML Página 31 de 76 Dimensiones del producto Freedom Par ...
Page 56: ...Página 56 de 76 Manual de Usuario serie Freedom Rev 6 ML Dimensions de l unité Freedom Par ...
Page 76: ......