Operation

IRC-6 Infrared Remote Control

The Freedom Flex H4 IP is compatible with the IRC-6 infrared remote control from Chauvet. To activate IR 

mode, follow the instructions below.

1.

Press 

<MENU>

 repeatedly until 

SEt

 shows on the display.

2.

Press 

<ENTER>

 to accept.

3.

Press 

<UP>

 or 

<DOWN>

 to select 

ON

 or 

OFF

.

4.

Press 

<ENTER>

.

IRC-6 Operation

Automatic Mode

Automatic mode will enable you to run the automatic programs on the product.

To turn on Automatic mode:

1.

Press 

<AUTO>

 on the IRC-6.

2.

Press 

<+>

 or 

<–>

 to choose between the different auto programs.

To select only fading programs:

1.

Press 

<FADE>

 on the IRC-6.

2.

Press 

<+>

 or 

<–>

 to choose between the different fading programs.

To adjust the speed of the automatic program:

1.

Press 

<SPEED>

 on the IRC-6.

2.

Press 

<+>

 or 

<–>

 to increase or decrease the speed of the program.

Manual Color Control

To select a preset static color with the IRC-6:

1.

Press 

<1>

<9>

 on the IRC-6.

To custom-mix a color with the IRC-6:

1.

Press 

<MANUAL>

 on the IRC-6, or skip to step 2.

2.

Select the color to be edited, from 

<R>

 (red), 

<G>

 (green), 

<B>

 (blue), 

<A>

 (amber), 

<UV/P>

 (UV), or 

<W>

. (white).

3.

Press 

<+>

 or 

<–>

 to increase or decrease the value of the selected color.

4.

Repeat steps 2 and 3 until the product outputs as desired.

Strobe

To adjust the strobe rate:

1.

Press 

<STROBE>

 on the IRC-6.

2.

Press 

<+>

 or 

<–>

 to increase or decrease the strobe rate.

3.

Press 

<STROBE>

 again to turn off the strobe.

Dimmer

To adjust the total output with the IRC-6:

1.

Press 

<%>

 on the IRC-6.

2.

Press 

<+>

 or 

<–>

 to increase or decrease the output level.

Black Out

To black out the lights:

1.

Press 

<BLACK OUT>

 on the IRC-6.

This will turn off all the lights until the button is pressed again.

NOTE: The IRC-6 will not respond to any inputs when Black Out is activated. If the 

remote does not respond when a button is pressed, try pressing 

<BLACK OUT>

You may have inadvertently activated Black Out.

Summary of Contents for FREEDOM FLEX H4 IP

Page 1: ...User Manual...

Page 2: ...he Battery 5 Charging the Battery 5 Battery Life Indicator 5 Battery Run Time 5 Battery Charge Notes 6 Mounting 6 Orientation 6 Rigging 6 4 Operation 7 Control Panel Operation 7 Menu Map 7 Wireless DM...

Page 3: ...Freedom Flex H4 IP X6 User Manual Rev 2 Table of Contents ii 5 Maintenance 14 Product Maintenance 14 6 Technical Specifications 15 Returns 16 Contact Us 17...

Page 4: ...Chauvet has no obligation to make and does not commit to make any such revisions Download the latest version from www chauvetdj com The works of authorship contained in this manual including but not l...

Page 5: ...cting this product must be within the range stated on the decal or rear panel of the product This product is for indoor or temporary outdoor use IP54 Do not expose to harsh or excessively corrosive en...

Page 6: ...The tabs on the Freedom Flex Battery will be fully extended when it is properly installed Ensure the Freedom Flex Battery is properly installed to preserve the product s IP rating Hex color LED x4 Squ...

Page 7: ...Using a flat head screwdriver unscrew the fuse holder cap from the housing 2 Remove the blown fuse 3 Replace with a fuse of the same type and rating 4 Screw the fuse holder cap back in place and reco...

Page 8: ...the case into a power source Battery Life Indicator The indicators on the LED Menu Display show how much battery life remains available The drawing below provides a key to reading the battery life ind...

Page 9: ...e safety recommendations indicated in the Safety Notes Orientation The Freedom Flex H4 IP may be mounted in any position however make sure adequate ventilation is provided around the product Rigging B...

Page 10: ...option or a selected value Mode Programming Levels Description DMX Mode 6 CH d 1 512 Sets DMX personality and starting address 8 CH 12CH Preset Colors C C 1 63 Selects a preset static color Automatic...

Page 11: ...ENTER Wireless DMX Configuration The Freedom Flex H4 IP offers wireless control of 2 or more products with a single DMX controller To set up the D Fi 2 4 GHz transceiver follow the instructions below...

Page 12: ...0 100 G 0 B 100 A 0 111 130 R 100 G 0 B 100 0 A 0 131 150 R 100 G 0 100 B 0 100 A 0 151 170 R 100 0 G 100 0 B 100 A 0 171 200 R 100 G 100 B 100 A 100 201 205 Color 1 206 210 Color 2 211 215 Color 3 21...

Page 13: ...100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 6 White 000 255 0 100 7 Ultraviolet 000 255 0 100 8 Strobe 000 010 No function 011 255 Strobe slow to fast Channel Function Value...

Page 14: ...ENU repeatedly until U shows on the display 2 Press ENTER and one of the following will appear r_ _ _ red g_ _ _ green b_ _ _ blue A_ _ _ amber W_ _ _ white P_ _ _ UV 3 Press ENTER to cycle through th...

Page 15: ...of the program Manual Color Control To select a preset static color with the IRC 6 1 Press 1 9 on the IRC 6 To custom mix a color with the IRC 6 1 Press MANUAL on the IRC 6 or skip to step 2 2 Select...

Page 16: ...Press MENU repeatedly until S tr shows on the display 2 Press ENTER 3 Use UP or DOWN to select drCH 4 Press ENTER 5 Use UP or DOWN to select the receiving D Fi channel from dr 1 16 6 Press ENTER 7 Fi...

Page 17: ...frequency To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to re...

Page 18: ...11 1 13 VDC 1 35 A Parameter 120 V 60 Hz 230 V 50 Hz Consumption 198 W 177 W Operating Current 1 6 A 0 9 A Fuse T 3 15 A 250 V T 3 15 A 250 V Power I O U S Worldwide UK Europe Power input connector p...

Page 19: ...rn To submit a service request online go to www chauvetdj com service request Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call...