Page 5 of 31
Setup
ÉPIX Flex Drive User Manual Rev. 1
3. Setup
AC Power
The ÉPIX Flex Drive has an auto-ranging power supply and it can work with an input voltage range of 100
to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under normal conditions.
AC Plug
The ÉPIX Flex Drive comes with a power input cord terminated with an IEC connector on one end and an
Edison plug on the other end (U.S. market). If the power input cord that came with your product has no
plug, or if you need the change the plug, use the table below to wire the new plug.
Fuse Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the
exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
•
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or
fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
•
Disconnect the product from power before replacing a blown fuse.
•
Always replace the blown fuse with another of the same type and rating.