3. Hardware Setup
AC Power
Warning!
Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
•
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
•
A fixture’s listed current rating is its average current draw under normal conditions.
•
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
•
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
•
All fixtures must be connected to circuits with a suitable Earth Ground.
P o w e r C a b l e C o n f i g u r a t i o n
C
ABLE
Pin
International
Screw Color
B
ROWN
Live
L
Yellow or Brass
B
LUE
Neutral N
Silver
Y
ELLOW
/G
REEN
Earth
EG (Ground)
Green
System Limitations
V
ERTICAL
P
ANELS
(
DOWN
)
M
INIMUM
1 panel = 16 rows of LED clusters or 16 vertical pixels/lines
M
AXIMUM WITH
1
D
RIVER
16 panels = 256 rows of LED clusters or 256 vertical pixels/lines
M
AXIMUM WITH
2+
D
RIVERS
32 panels = 512 rows of LED clusters or 512 vertical pixels
H
ORIZONTAL
P
ANELS
(
ACROSS
)
M
INIMUM
1 panel = 16 columns of LED clusters or 16 horizontal pixels/lines
M
AXIMUM WITH
1
D
RIVER
6 panels = 96 columns of LED clusters or 96 horizontal pixels/lines
M
AXIMUM WITH
2+
D
RIVERS
48 panels = 768 columns of LED clusters or 768 horizontal pixels
RESOLUTION
M
INIMUM
16 pixels X 16 pixels
M
AXIMUM WITH
1
D
RIVER
96 pixels X 128 pixels
M
AXIMUM WITH
2+
D
RIVERS
768 pixels X 512 pixels
DV Wall System User Manual
7
2007-02-05
/
16:45