Chauvet DMX-605A Intimidator 2.0 User Manual Download Page 11

 

DMX-605A & DMX-610A User Manual 

11 

2005-11-16/16:16

 

A

PPENDIX

 

DMX Primer 

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A 

fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user 

must assign a starting address on the fixture that indicates the first channel reserved in the controller. 

There are many different types of DMX controllable fixtures and they all may vary in the total number 

of channels required. Choosing a start address should be planned in advance. Channels should 

never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is 

set incorrectly. You can however, control multiple fixtures of the same type using the same starting 

address as long as the intended result is that of unison movement or operation. In other words, the 

fixtures will be slaved together and all respond exactly the same.  

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is 

where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which 

the fixtures are connected is not important and has no effect on how a controller communicates to 

each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures 

using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The 

shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET 

carries 3-pin XLR DMX compliant cables, DMX-10 (33

), DMX

-4.5 (15

) and DMX

-1.5 (5

)

 

F I XT U R E  L I N K I N G  

 

 

 

 

 

Note! 

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 
pin to 3 pin adapter. CHAUVET Model No: DMX5M. 
The chart below details a proper cable conversion: 
 

3

 

P

IN TO 

5

 

P

IN 

C

ONVERSION 

C

HART

 

C

ONDUCTOR

 

3 Pin Female (output) 

5 Pin Male (Input) 

G

ROUND

/S

HIELD

 

Pin 1 

Pin 1 

D

ATA 

(

 

-

 

)

SIGNAL

 

Pin 2 

Pin 2 

D

ATA 

(

 

+

 

)

 SIGNAL

 

Pin 3 

Pin 3 

D

O NOT USE

 

 

Do not use 

D

O NOT USE

 

 

Do not use 

 

COMMON 

DMX + 

DMX - 

INPUT 

OUTPUT 

3

Resistance 120 
ohm 1/4w between 
pin 2 (DMX -) and 
pin 3 (DMX +) of 
the last fixture. 

Termination reduces signal errors and to 
avoid signal transmission problems and 
interference, it is always advisable to connect 
a DMX signal terminator. 

Figure 2 - DMX connector configuration 

Summary of Contents for DMX-605A Intimidator 2.0

Page 1: ...000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 11 16 16 16 DMX 605A Intimidator 2 0 DMX 610A Insignia 2 0 USER MANUAL Insignia 2 0 Intimidator 2 0 ...

Page 2: ...TUP 6 LAMP 6 Lamp installation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 MANUAL FOCUSING 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 DMX Mode 8 Setting the starting address 8 CA 9 EASY CONTROLLER OPTIONAL 10 APPENDIX 11 DMX PRIMER 11 Fixture Linking 11 DMX CHANNEL VALUES 12 MAINTENANCE 13 RETURNS PROCEDURE 13 CLAIMS 13 GEN...

Page 3: ... Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk ...

Page 4: ...2 metal 2 glass Gobo Bounce Color Wheel 11 colors plus open include UV purple plus white Pan 180 in 5 sec Tilt 90 in 3 sec Features Built in beat activated and automatic programs stand alone Double bracket yoke doubles as floor stand Bulb saver cuts off after 10 seconds Surface coated mirror for optimum luminosity Automatically enters stand alone when no DMX signal is present Linkable via Master S...

Page 5: ...or 2 0 Insignia 2 0 Mirror Scanner Barrel Scanner Hanging Yoke double bracketed for floor positioning Double bracketed yoke used for floor positions Lamp access cover Power Fuse compartment Microphone Sound Sensitivity Knob Voltage Switch Remote Controller Input DMX connectors ...

Page 6: ...rom the lamp socket and replace 5 Replace lamp face plate align the screw holes and fasten the thumbscrews 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the reflector Power Your product is equipped with switch selectable AC power setting Warning Verify that the power select switch on your unit matches the line voltage applied All fixtures must be conn...

Page 7: ...ce o Safety cables should always be used o Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with ...

Page 8: ...low MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the f...

Page 9: ...ovide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not cause a negative number EXAMPLE STARTING ADDRESS Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8 Total 24 Resolving address using simple math Address...

Page 10: ...tton Tap the Function button to step through the 11 colors then once more to step to the next gobo BLACKOUT LED OFF Fast Mode The unit s movement Pan Tilt and Gobo Color is sound activated Press and hold the Function button to achieve the following results a Strobe in different colors and gobos b Synchronous strobe in white c Two light strobe in white color CA 9 Easy Controller Optional ...

Page 11: ...of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whi...

Page 12: ...119 120 127 128 255 Gobo Blackout Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo Spin Slow Fast 3 000 010 011 012 022 023 033 034 044 045 055 065 066 076 077 087 088 098 099 109 110 120 121 127 128 255 Color Open White Red Dark Blue Yellow Green Pink UV Cyan Orange Magenta Tri Color Red White Blue Quad Color Color Spin Slow Fast 4 0...

Page 13: ...nds on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent pr...

Page 14: ... Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor move...

Page 15: ... 60320 C14 male socket Current draw peak 264W 120V inrush 598W 120V European version 230V 240V 50 Hz LAMPS ELC 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 6 3A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 5 ORDERIN...

Reviews: