3. Setup 

9/10/2010 3:56 PM  

3.

 

S

ETUP

 

 

 

AC Power 

 

 

 

This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line 

voltage to which you are connecting it is within the range of accepted voltages. 

 

To determine the power requirements for a particular fixture, see the label affixed to the back 
plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating 

indicates its average current draw under normal conditions.  

 

 

 

Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only 

as a 0 to 100% switch.

 

 

 

 

Always connect the fixture to a circuit with a suitable electrical ground.  

 

 

Power Linking 

 

 

 

This fixture contains power linking via the Edison outlet located in front of the power input cable. 

Please see the diagram below for further explanation. 

 

 

 

The maximum quantity of 

Cosmos™ LEDs that may be linked is 24.

 

 

 

 

 

 

 

 

The power linking shown in this document is for the Chauvet® North American version 
ON

LY! Therefore, it is the customer’s responsibility to check with the Dealer/Distributor 

regarding power linking on the local version of the product. Connections and availability 
may change, depending on the power requirements and/or regulations of each 
country/region. 

 

 

 

Additional power 

link out 

Fixture 3 

Fixture 2 

Fixture 1 

 

Summary of Contents for Cosmos LED

Page 1: ...User Manual...

Page 2: ...nual Rev01 TABLE OF CONTENTS 1 BEFORE YOU BEGIN 3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 ICONS 3 SAFETY INSTRUCTIONS 4 2 INTRODUCTION 5 PRODUCT OVERVIEW 5 3 SETUP 6 AC POWER 6 Power Linking 6 MOU...

Page 3: ...the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Icons This manual uses the following icons to indicate inf...

Page 4: ...t from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C...

Page 5: ...2 Introduction 5 9 10 2010 3 56 PM 2 INTRODUCTION Product Overview Back Panel Power In Fuseholder Motor Rotation Speed Adjustment Knob Power Out...

Page 6: ...circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power lin...

Page 7: ...hole in each bracket is 13 mm in size When rigging consider routine maintenance and control panel access Please see the following steps for installation You may set this on a surface using the four ru...

Page 8: ...TRUCTIONS Adjusting the Rotation Speed The rotation speed of this product may operate from 0 100 Use the rotation adjustment knob to adjust the speed The LEDs will change to the beat of the music usin...

Page 9: ...load Check total load placed on the electrical circuit Short circuit along the power wires Check for a short in the electrical wiring internal and or external Device does not power up No power Check f...

Page 10: ...riginal packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUVET and reque...

Page 11: ...max Power Consumption 230 V 10 W 0 1 A max Power output 24 units max LIGHT SOURCE Type Tri color LEDs Quantity 4 red 350 mA 4 green 350 mA 4 blue 350 mA Rating 50 000 hrs PHOTO OPTIC Coverage angle 3...

Page 12: ...0 NW 108th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Atte...