 DMX Channel Values  

 

D

EFAULT

 

V

ALUE

 

F

UNCTION

 

 

000 

 009 

010 

 019 

020 

 029 

030 

 039 

040 

 049 

050 

 059 

060 

 069 

070 

 079 

080 

 089 

090 

 099 

100 

 109 

110 

 119 

120 

 129 

130 

 139 

140 

 149 

150 

 159 

160 

 169 

170 

 179 

180 

 189 

190 

 199 

200 

 209 

210 

 219 

220 

 255 

Programs 
Black 
Red 
Green 
Blue 
Yellow 
Purple 
Light Blue 
White 
Color Change 
Slow Flow 1 
Slow Flow 2 
Roll Chase 1 
Roll Chase 2 
Multi Color 
Fast Flow 1 
Fast Flow 2 
Fast Flow 3 
Fast Flow 4 
2 Color Chase 
2 Color Flow 
Any Color: Activates Red, Green & Blue Intensity controls 
Color Fade 
Auto Run 

Run Speed 
Slow  > Fast, (1 step/Minute) > (100 steps/Second) 

 

000 

 255 

Any Color (Active) 
Red: Intensity: 0% > 100 

 

000 

 002 

003 

 249 

250 

 255 

Flash Speed 
Always On 
Slow > Fast 
Blackout 

 

000 

 255 

Any Color (Active) 
Green: Intensity: 0% > 100 

 

000 

 012 

013 

 025 

026 

 038 

039 

 051 

052 

 064 

065 

 077 

078 

 090 

091 

 103 

104 

 116 

117 

 129 

130 

 142 

143 

 155 

156 

 168 

169 

 181 

182 

 194 

195 

 207 

208 

 220 

221 

 233 

234 

 246 

247 

 255 

Color Combinations 
Red & Green 
Red & Yellow 
Red & Blue 
Red & Purple 
Red & Cyan 
Red & White 
Green & Yellow 
Green & Blue 
Green & Purple 
Green & Cyan 
Green & White 
Yellow & Blue 
Yellow & Purple 
Yellow & Cyan 
Yellow & White 
Blue & Purple 
Blue & Cyan 
Blue & White 
Purple & Cyan 
Purple & White 

 

000 

 255 

Any Color (Active) 
Blue: Intensity: 0% > 100 

 

Refer to the Single Actions Program Chart on page 8 to determine if a 
Run Speed, Flash Speed and/or Color Combinations become 
functional. Not all functions are available to all preset programs listed.  

Summary of Contents for COLORMIST MIST-CON

Page 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 10 10 18 36 COLORmist System MIST PAR80 COLORmist Par MIST PANEL COLORmist Panel MIST CON COLORmist Controller MIST PS8 COLORmist Power Unit USER MANUAL ...

Page 2: ...IST PAN 6 OPERATING INSTRUCTIONS 7 CONTROL PANEL 7 MENU DIAGRAM 7 SYSTEM SETUP 7 Initial Setup 7 Re initialization 7 SINGLE ACTION PROGRAMS 8 Choosing Single Action Programs 8 DMX CONTROL MODE 9 Setting the DMX address 9 Running in DMX Mode 9 Daisy Chain Connection 9 SYSTEM CONFIGURATION CONNECTION 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MIST PS8 POWER UNIT CONFIGURATI...

Page 3: ...tage selection switch exists that it is set to the correct line voltage you will use Warning If applicable verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive...

Page 4: ... 24 Ultra bright LED s Stand alone color change programs using COLORmist Power unit 7 static colors 13 color pattern chase programs with adjustable speeds auto run sound active mode and RGB Mix via MIST CON COLORmistTM Controller Low power consumption and heat generation No infra red or UV emissions Up to 100 000 hour LED life span Master Slave mode requires COLORmist Power unit MIST PAR80 and MIS...

Page 5: ...X input connector C Power and Signal output D DC input External Power Supply C D COLORmist Controller Rear Panel COLORmist Hanging yoke Input and Output 4 conductor connectors Used for both power and signal COLORmist Power 8 AC Voltage Switch Power connector Fuse compartment 4 conductor connectors provide signal and power continuation for daisy chained fixtures COLORmist Rear Panel COLORmist Power...

Page 6: ...ure check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground Mounting MIST PAR80 Orientation This fixture can be mounted on a truss using a clamp in any position or on a strut system for track style lighting Riggin...

Page 7: ...he display shows M System Setup 2 Press the SETUP button then the UP button once It will show 3 Lamp Amount 3 Press the SETUP button to enter the function A number will now appear to the right of the text as shown here in an example 3 Lamp Amount 34 4 Use the UP and DOWN buttons to locate a number between 0 and 250 This represents the number of fixtures connected 5 Press the MODE button to set thi...

Page 8: ...Run Speed Flash Speed Select Color Combination 1 20 2 Color Flow Auto Run Speed Flash Speed Select Color Combination 1 21 Any Color RGB Color Mix Red Green Blue 22 Color Fade Auto Run Speed 23 Auto Run Auto Run Speed runs all built in programs 1 Refer to DMX Channel Values for Color Combinations Table Choosing Single Action Programs 1 Press the MODE button until the display shows M System Setup 2 ...

Page 9: ...nnel values The next step may require you to create a device profile within your lighting controller Proceed to section DMX Channel Values for a detailed chart of the control values for each channel of DMX Running in DMX Mode If the control panel menu displays 1 Dmx Ch press SETUP to activate DMX control mode For instructions on arriving at this menu item repeat the instructions Setting the DMX ad...

Page 10: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Page 11: ...cond 2 000 255 Any Color Active Red Intensity 0 100 000 002 003 249 250 255 Flash Speed Always On Slow Fast Blackout 3 000 255 Any Color Active Green Intensity 0 100 000 012 013 025 026 038 039 051 052 064 065 077 078 090 091 103 104 116 117 129 130 142 143 155 156 168 169 181 182 194 195 207 208 220 221 233 234 246 247 255 Color Combinations Red Green Red Yellow Red Blue Red Purple Red Cyan Red W...

Page 12: ...nd in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping dama...

Page 13: ...8 38 in Height 47 63 mm 1 88 in Weight 0 70 Kgs 1 55 lbs Power 12V DC 800mA Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT Channels 4 ORDERING INFORMATION COLORmist MIST PAR80 COLORmist Panel MIST PANEL COLORmist Power 8 MIST PS8 COLORmist Controller MIST CON COLORmist Power Signal Cable 3...