Chauvet COLORDASH S-PAR 1 User Manual Download Page 10

 
Setup

 

-6- 

 

COLORdash S-Par 1 User Manual Rev. 2 

3. Setup 

AC Power 

Each COLORdash S-Par 1 has an auto-ranging power supply that works with an input voltage 
range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each  
COLORado 1 Solo, refer to the label affixed to the product. You can also refer to the 

Technical 

Specifications

 chart in this manual. 

The listed current rating indicates the maximum current draw during normal operation. For more 
information, you may download Sizing Circuit Breakers from the Chauvet  website: 

www.chauvetprofessional.com

. 

 

 

Always connect this product to a protected circuit with an appropriate electrical 
ground to avoid the risk of electrocution or fire. 

 

To eliminate unnecessary wear and improve its lifespan, during periods of non-use 
completely disconnect the product from power via breaker or by unplugging it. 

 

Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the 
rheostat or dimmer channel serves only as a 0 to 100% switch. 

AC Plug 

The  COLORdash S-Par 1  comes  comes with a power input cord terminated with a Seetronic 
Powerkon  A connector on one end and an Edison plug on the other end (U.S. market). If the 
power input cord that came with your product has no plug, or if you need to change the Edison 
plug, use the table below to wire the new plug. 

 

Connection 

Wire (U.S.) 

Wire (Europe) 

Screw Color 

AC Live 

Black 

Brown 

Yellow or Brass 

AC Neutral 

White 

Blue 

Silver 

AC Ground 

Green/Yellow 

Green/Yellow 

Green 

 

Power Linking 

The  COLORdash S-Par 1  supports power linking. You can power link up to 24  products at  
120 V; up to 40 at 208 V; or up to 45 at 230 V. 
This product comes with a power input cord. Power linking cables are available from Chauvet 
for purchase. 

 

 

To preserve the IP65 rating and the warranty of this product, Seetronic Powerkon 
cables must be used. 

 

Insert the attached IP65 rated plugs into the corresponding power/data connections 
when not in use. 

 

 

Summary of Contents for COLORDASH S-PAR 1

Page 1: ...User Manual...

Page 2: ...ual or its content for any other purpose without written consent from Chauvet Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A...

Page 3: ...inking 7 DMX Personalities 7 Master Slave Connectivity 7 Mounting 8 Orientation 8 Rigging 8 Procedure 8 4 Operation 9 Control Panel Description 9 Control Options 9 Programming 9 Control Panel Lock 9 P...

Page 4: ...Table of Contents ii COLORdash S Par 1 User Manual Rev 2 Product Maintenance 16 6 Technical Specifications 17 Returns 18 Contact Us 19...

Page 5: ...entions Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text SET A button on the product s control panel Settings A product function or a menu op...

Page 6: ...now Other areas where the product will be subject to extreme radiation or caustic substances Mount this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Make...

Page 7: ...mount or hanging support bracket Features 4 6 or 11 channel quad color LED wash product Operating modes 4 channel RGBA 6 channel RGBA dimmer strobe 11 channel RGBA dimmer strobe color macro white bala...

Page 8: ...Introduction 4 COLORdash S Par 1 User Manual Rev 2 Overview Front View Rear View Side View Control Panel LED Power In Data Out Power Out Adjustment Knob Double Bracket Yoke Top View Data In...

Page 9: ...Introduction COLORdash S Par 1 User Manual Rev 2 5 Dimensions 9 09 in 231 mm 6 68 in 169 mm 8 39 in 213 mm 12 32 in 313 mm 7 32 in 186 mm...

Page 10: ...nect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch AC Plug The COLORdash S Par 1 comes comes with a power input...

Page 11: ...essional com Master Slave Connectivity The Master Slave mode allows a COLORdash S Par 1 the master to control one or more COLORdash S Par 1s the slaves without a DMX controller One COLORdash S Par 1 b...

Page 12: ...lammable material as indicated in the Safety Notes If hanging this product make sure that the mounting location can support the product s weight See the Technical Specifications for the weight bearing...

Page 13: ...he desired main level press MENU repeatedly until the option shows on the display Press ENTER to select This will take you to the first programming level for that option To select an option or value w...

Page 14: ...mer speed Static Fixed Color R Red G Green B Blue A Amber GB Green Blue RB Red Blue RG Red Green RGB Red Green Blue RA Red Amber GA Green Amber BA Blue Amber RGA Red Green Amber RBA Red Blue Amber GBA...

Page 15: ...red LED maximum value G Sets green LED maximum value B Sets blue LED maximum value LED Frequency 600Hz Selects the PWM output frequency 1200Hz 2000Hz 4000Hz 25KHz Key Lock On Turns the passcode on or...

Page 16: ...shown by the COLORdash S Par 1 when the color setting is RGBA and the DMX controller s red green and blue faders are set to 255 1 Go to the White Balance main level 2 Select Manual to continue to adju...

Page 17: ...trol panel 1 Go to the Back Light main level 2 Select On remains on 10S 10 seconds 20S 20 seconds or 30S seconds Fixture Hours Software Version This option displays the total number of hours the fixtu...

Page 18: ...00 B 100 A 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 8 Color Temperature 000 005 006 025 026 050 051 075 076 100 101 125 126 150 151 175 176 200 201...

Page 19: ...nt Setting 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 Amber 000 255 0 100 6 Strobe 000 010 011 255 No function Slow to fast 4 Ch Channel Function Value Per...

Page 20: ...ncreased mechanical wear To clean your product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust coll...

Page 21: ...45 products Power I O U S Canada Worldwide Power input connector Seetronic Powerkon IP65 A Seetronic Powerkon IP65 A Power output connector Seetronic Powerkon IP65 B Seetronic Powerkon IP65 B Power c...

Page 22: ...th an RMA number Chauvet will refuse any product returned without an RMA number DO NOT write the RMA number directly on the box Instead write it on a properly affixed label Once you have received the...

Page 23: ...ting eu Website www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 51111...

Reviews: