Before You Begin 

 
 

COLORdash™ Batten-Tri User Manual Rev. 02a 

 

-1- 

1. Before You Begin 

   

 

What is 

Included 

 

 

One COLORdash™ Batten-Tri 

 

One power input cord 

 

Warranty Card 

 

Quick Reference Guide 

   

 

Unpacking 

Instructions 

 

Immediately upon receiving this product, carefully unpack it and check the container in 
which you received it.  Make sure that you have received all  the parts indicated above 
and that they are all in good condition. If the material inside the container (this product 
and any other accessory included with it)  appears  damaged from shipping,  or  if  the 
container shows signs of mishandling, notify the shipper immediately. In addition, retain 
the container and all the packing material for inspection.  

See the 

Claims

 section in the 

Technical Information

 chapter. 

   

 

Typographic 

Conventions 

 

Convention 

Meaning 

1~512 

A range of values in the text 

50/60 

A set of mutually exclusive values in the text 

[10] 

A DIP switch to be configured 

Claims 

A new term, or a section or chapter in this document 

“COLORado™ UM”  The name of another publication or manual 

<SET> 

A button on the fixture’s control panel 

Settings 

A fixture function or a menu option  

MENU > Settings 

A sequence of menu options 

1~10 

A range of menu values from which to choose in a menu 

Yes/No 

A set of two mutually exclusive menu options in a menu 

ON 

A unique value to entered or select in a menu 

   

 

Icon Meaning 

 

Icon 

Meaning 

 

This icon indicates critical installation, configuration, or operation 
information. Failure to comply with this information may render 
the fixture partially or completely inoperative, damage third-party 
equipment, or cause harm to the user. 

 

This icon indicates important installation or configuration 
information. Failure to comply with this information may prevent 
the fixture from functioning correctly. 

 

This icon indicates useful, although non-critical information. 

   

 

 

 

The term “DMX” used  throughout this document refers to the USITT DMX512-A 
transmission protocol. 

   

 

 
 
 

 

Summary of Contents for ColorDash Batten-Tri

Page 1: ...User Manual...

Page 2: ...97 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the COLORdash Batten Tri should read th...

Page 3: ...ew 5 3 Setup 6 AC Power 6 AC Plug 6 Power Linking 6 Fuse Replacement 6 DMX Linking 6 DMX Modes 6 Master Slave Connectivity 6 Mounting 7 Orientation 7 Rigging 7 4 Operation 8 Control Panel Description...

Page 4: ...OLORdash Batten Tri User Manual Rev 02a 5 Technical Information 17 General Maintenance 17 Photometrics 17 Troubleshooting Guide 18 Exploded View 19 Returns Procedure 20 Claims 20 Contact Us 20 Technic...

Page 5: ...xclusive values in the text 10 A DIP switch to be configured Claims A new term or a section or chapter in this document COLORado UM The name of another publication or manual SET A button on the fixtur...

Page 6: ...roduct always secure it to a fastening device using a safety chain cable not included Power and Wiring Always make sure that you are connecting this product to the proper voltage as per the specificat...

Page 7: ...channel HSV control 3 channel RGB control 4 channel RGB dimmer 11 channel RGB dimmer color macro strobe auto custom fan speed auto program speed module select ID addressing dimmer speed 24 channel RGB...

Page 8: ...l 1 blue 4 Pixel 2 red 5 Pixel 2 green 6 Pixel 2 blue 7 Pixel 3 red 8 Pixel 3 green 9 Pixel 3 blue 10 Pixel 4 red 11 Pixel 4 green 12 Pixel 4 blue 13 Pixel 5 red 14 Pixel 5 green 15 Pixel 5 blue 16 Pi...

Page 9: ...Introduction COLORdash Batten Tri User Manual Rev 02a 5 Product Overview A 125 mm B 13 mm Control Panel Fan DMX In Power In Power Out DMX Out Fuse...

Page 10: ...type and rating Power Linking The COLORdash Batten Tri supports power linking for up to 12 other similar fixtures at 120 VAC Although this fixture comes with a power input cord it comes with no power...

Page 11: ...to mount this fixture away from any flammable material as indicated in the Safety Notes section Rigging CHAUVET recommends following the general guidelines below when mounting the COLORdash Batten Tr...

Page 12: ...e line program no more than 10 fixtures on ID addressing per DMX channel This is to remain within a one second execution time Programming Carry out all the programming procedures indicated below from...

Page 13: ...ash Batten Tri fixtures the slaves to execute simultaneously the same program whether auto or custom that another COLORdash Batten Tri fixture the master is executing and without a DMX controller 1 Se...

Page 14: ...custom programs of one COLORdash Batten Tri fixture onto other COLORdash Batten Tri fixtures by using the Master Slave method 1 Configure and connect the fixtures in a Master Slave arrangement where...

Page 15: ...3 Select a color RED GREEN or BLUE 4 Select a color value 0 255 5 Repeat for the other colors The values of RED GREEN and BLUE configured from CALIB2 RGB TO W will define the color temperature shown w...

Page 16: ...ntensity Channel 6 strobes channel 5 when running macros allowing channel 5 to select the macro and channel 1 to control the output intensity Auto Channel 7 selects the fans speed the preset auto prog...

Page 17: ...Operation COLORdash Batten Tri User Manual Rev 02a 13 Menu Map...

Page 18: ...te 6 5 900 K White 7 6 500 K White 8 7 200 K White 9 8 000 K White 10 8 500 K White 11 10 000 K 6 Strobe 000 009 010 255 No function 1 20 Hz 7 Auto Custom Programs Fan Control 000 010 011 020 021 030...

Page 19: ...l 1 Blue 000 255 0 100 4 Pixel 2 Red 000 255 0 100 5 Pixel 2 Green 000 255 0 100 6 Pixel 2 Blue 000 255 0 100 7 Pixel 3 Red 000 255 0 100 8 Pixel 3 Green 000 255 0 100 9 Pixel 3 Blue 000 255 0 100 10...

Page 20: ...100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 HSV Channel Function Value Percent Setting 1 Hue 000 255 0 100 2 Saturation 000 255 0 100 3 Value 000 255 0 100 Hue refers to the vis...

Page 21: ...w Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable internal components Clea...

Page 22: ...e or damaged power cord Check power cord Blown fuse Replace fuse Faulty internal power supply Replace internal power supply Fixture does not respond to DMX Wrong DMX addressing Check Control Panel and...

Page 23: ...ription 1 Clear front plate 2 Lens holder 3 Individual lenses 8 4 LED board 5 Side panel 2 6 Tilt adjust knob 2 7 LED driver board 8 Power supply 9 Display board 10 Back cover 11 Fan 12 3 pin XLR sock...

Page 24: ...ing will be the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace r...

Page 25: ...50 Hz Consumption 38 W 0 56 A 36 W 0 3 A Inrush current 0 3 A 0 3 A Power I O Input Output Connectors IEC IEC Cord plug Edison N A Fuse Type Fuse Rating Fuse Size Glass F 1 5 A fast blow 20 mm Light S...

Page 26: ...CHAUVET 5200 NW 108th Avenue Sunrise FL 33351 USA 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com COLORdash Batten Tri User Manual Rev 02a October 2010...

Reviews: