background image

 

 

 

 

Appendix 

LED-BAR User Manual 

 

2005-11-22/09:18 

DMX Control Mode 

Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to 

customizing or creating a show.  In this mode you will be able to control each individual trait of the 

fixture and each fixture independently.  

1.  Enable DMX control by setting SLA to ON in the control panel.  

2.  Address each fixture accordingly using the CHA function. 

S e t t i n g   t h e   D M X  a d d r e s s  

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start 

address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data 

on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels 

of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 

102, 103, 104, 105 and 106. Choose start addresses so that the channels used do not overlap and 

notate the start address selected for future reference.  

If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping 

to the Appendix Section and read the heading 

DMX Primer

. It contains very useful information that 

will help you understand its use.  

1.  Press the [MENU] button on the control panel until the display reads [



]. 

2.  Use the [UP] and [DOWN] buttons to increase or decrease channel values until the desired value 

is displayed. 

3.  Remember to set function [



] to ON in order to enable DMX control.   

Summary of Contents for COLORbar LED-BAR

Page 1: ...CHAUVET 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 11 22 09 18 LED BAR COLORbar USER MANUAL ...

Page 2: ...UNTING 6 OPERATING INSTRUCTIONS 7 CONTROL MENU FUNCTIONS 7 APPLYING CHANGES TO FUNCTIONS 7 MASTER SLAVE STAND ALONE MODES 7 Program Control Options 8 Daisy Chain Connection 8 DMX CONTROL MODE 9 Setting the DMX address 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 17 Channel Mode 11 5 Channel Mode 11 6 Channel Mode Auto Sound Active 12 RETURNS PROCEDURE 12 CLAIMS 12 TECHNICAL...

Page 3: ...r Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fix...

Page 4: ...lor 1 4 Color 2 5 Speed 6 Fade 6 Channel Configuration Auto Run Sound Active INTRODUCTION Features CONTROL FEATURES 5 17 channel DMX 512 LED panel system Operating modes 17 channel mode 4 sections of RGB mix control 5 channel mode RGB mix control of all sections 6 channel mode Automatic Adjust or change program color speed and fade 6 channel mode Sound Active Adjust or change program color speed a...

Page 5: ...on LED BAR User Manual 5 2005 11 22 09 18 Control Panel DMX Input Fuse Switch selectable AC Voltage Hanging yoke Sound sensitivity knob Power Switch IEC Plug for AC Input DMX Output IEC AC Output Product Overview ...

Page 6: ...ered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATION...

Page 7: ...Fade SLA ON Slave OFF Master ON is necessary for DMX control Color Tables NO 0 1 2 3 4 5 6 7 Color Blackout Red Green Blue Yellow Magenta Cyan White Applying changes to Functions 1 Press the MENU button repeatedly until the display reads the menu function you wish to change 2 Press the DOWN or UP buttons to toggle or scroll through values that pertain to that function Master Slave Stand Alone Mode...

Page 8: ...anges to the internal programs You can choose from 10 preset program patterns Pattern 0 is a fully automatic multi colored chase program The remaining patterns 1 9 are 2 color chases and the user can select alternating colors from the list of colors available in the Color Table The speed of the running programs can be adjusted for all patterns unless in Sound Active mode A cross fade function allo...

Page 9: ... to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference If this is your first time addressing a fix...

Page 10: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Page 11: ...ic run 6 Channel Mode Sound Active 17 Channel Mode CHANNEL VALUE FUNCTION 2 000 255 Red 0 100 3 000 255 Green 0 100 4 000 255 Blue 0 100 5 000 255 Dimmer 0 100 Section 1 6 000 255 Red 0 100 7 000 255 Green 0 100 8 000 255 Blue 0 100 9 000 255 Dimmer 0 100 Section 2 10 000 255 Red 0 100 11 000 255 Green 0 100 12 000 255 Blue 0 100 13 000 255 Dimmer 0 100 Section 3 14 000 255 Red 0 100 15 000 255 Gr...

Page 12: ... Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own...

Page 13: ...aw peak 15W 120V FUSE Main 20mm Glass 1A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 5 17 ORDERING INFORMATION COLORbar LED BAR Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting co...

Reviews: