Remove screws on both sides. 

Figure 2 

 CH-222 Lamp installation 

Lamp exposed 

Figure 3 - Hanging Clamp 

S

ETUP

 

Lamp 

You will need to install a lamp prior to the initial operation of the fixture. An EFP 100W halogen lamp 

is included.  

Warning! 

When replacing the lamp, please wait 15 minutes after powering down to allow the 
unit to cool down! Always disconnect from main power prior to lamp replacement. 

Do not touch the envelope (glass area) of the bulb with 

bare hands. If this happens, clean the lamp with alcohol 

and wipe it with a lint free cloth before installation. 

L AM P   I N ST AL L AT I O N  

1) 

Remove the four screws located on both sides of 
the fixture and remove fixture cover. 

2) 

If replacing the lamp, remove old lamp first. 

3) 

Reach in and slide the lamp out of the retaining 
cage. 

4) 

Detach the lamp from the lamp socket and 
replace. 

5) 

Replace fixture cover, align the screw holes and 
fasten the screws. 

6) 

No lamp alignment is necessary for this fixture 
since the lamp is already optimized inside the 
reflector. 

 

Mounting 

O R I E N T AT I O N  

This fixture may be mounted in any position provided there is adequate room for ventilation.  

R I G G I N G    

It is important never to obstruct the fan or vents pathway. Mount the 

fixture using, a suitable 

C

 or 

O

 type clamp. Ad

just the angle of the 

fixture by loosening both knobs and tilting the fixture. After finding the 

desired position, retighten both knobs. 

 

When selecting installation location, take into consideration lamp 
replacement access and routine maintenance.  

 

Safety cables should always be used.  

 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature 
changes or restricted ventilation. 

 

Note! 

Clamps sold separately!

Summary of Contents for ABYSS JR.

Page 1: ...Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 07 22 17 40 CH 222 Abyss Jr USER MANUAL ...

Page 2: ...G INSTRUCTIONS 3 POWER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 OPERATING INSTRUCTIONS 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Page 3: ...ll the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there ...

Page 4: ...ulation effect on a wall or any flat surface It is a wonderful scenic effect that adds life and color to any venue Features water undulation effect wave effect bright EFP5 100w MR 16 lamp fan cooled Product Overview Hanging Bracket Lamp access Power connector Figure 1 Product Overview ...

Page 5: ...ch in and slide the lamp out of the retaining cage 4 Detach the lamp from the lamp socket and replace 5 Replace fixture cover align the screw holes and fasten the screws 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the reflector Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It...

Page 6: ...use the latest in DMX compatible Dimmer Relay Pack all available from CHAUVET A relay system will allow you to remotely trigger the Abyss Jr and any other non dimmable effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile lighting applications If you would prefer to control it directly f...

Page 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Page 8: ...ly in order to measure correctly check to see if perhaps it is stuck Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick st...

Page 9: ...ong IEC 60320 C14 LAMPS EFP5 50 hr 100W 12v THERMAL Maximum ambient temperature 40 104 F FUSE Main 115V AC 20mm Glass 2A Fast Blow Main 230V AC 20mm Glass 1A Fast Blow ORDERING INFORMATION Abyss Jr CH 222 Fuse 2A P170FUSE002 Fuse 1A P170FUSE001 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone 954 929 1115 Press 4 Fax 95...

Reviews: