EN
2
Ovation P-56VW QRG Rev. 7
QUICK REFERENCE GUIDE
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
It is possible to link up to 11 Ovation P-56VW products at 120 VAC, 18 products at 208 V, or 20 products at 230 VAC.
Never exceed this number. Power-linking cords can be purchased separately.
AC Plug
Replacing the Fuse
1.
Disconnect this product from power.
2.
Using a flathead screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Ovation P-56VW will work with a DMX controller using a 3- or 5-pin DMX serial connection. A DMX Primer is
DMX Connection
The Ovation P-56VW uses a 3- or 5-pin DMX data connection for its DMX personalities:
1Ch
,
3Ch
,
5Ch
,
6Ch
,
8Ch
,
11Ch
,
15Ch
, and
18Ch
. See the User Manual for information about connecting and configuring the product for DMX operation.
Master/Slave Connection
The Ovation P-56VW uses the DMX data connection for its master/slave mode. See the User Manual for information
about how to connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check with the manufacturer or the DMX controller’s User Manual, as not all DMX controllers
have this capability. The Ovation P-56VW supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from
for more details.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely